A selective spectrophotometric method for determination of copper with ferron
Talanta
|February 1, 1987
Summary
This study presents a selective spectrophotometric method for determining copper using the copper-ferron complex. The method allows for accurate copper quantification up to 8 microg/ml with minimal interference from other elements.
Area of Science:
- Analytical Chemistry
- Spectrophotometry
Background:
- Accurate quantification of copper is crucial in various scientific fields.
- Existing methods for copper determination may lack selectivity or sensitivity.
Purpose of the Study:
- To develop a selective and sensitive spectrophotometric method for copper determination.
- To investigate the complexation and extraction behavior of copper.
Main Methods:
- Copper was complexed with ferron.
- The copper-ferron complex was extracted using tribenzylamine in chloroform.
- Absorbance was measured spectrophotometrically at 410 nm.
Main Results:
- The method demonstrated selectivity for copper, with only molybdenum interfering among 30 tested elements.
- Beer's law was obeyed for copper concentrations up to 8 microg/ml.
- The stoichiometry of the extracted complex was determined to be 1:2:2 (copper:ferron:tribenzylamine).
Conclusions:
- The developed spectrophotometric method offers a selective and sensitive approach for copper determination.
- The method is suitable for quantifying copper in samples where interference from other elements is a concern.
Related Concept Videos
Precipitation Titration: Endpoint Detection Methods
In argentometric precipitation titrations, endpoints can be detected visually by the Mohr, Volhard, and Fajans methods. In the Mohr method, adding a soluble chromate indicator gives an initial yellow color to the analyte solution. As the titrant is added, the first excess of silver ions forms a red silver chromate precipitate, marking the endpoint. The solution pH should be maintained at about 8 by adding solid CaCO3.
In the Volhard method, a standard excess of AgNO3 is first added to the...
In the Volhard method, a standard excess of AgNO3 is first added to the...
Precipitation and Co-precipitation
Precipitation and coprecipitation methods can be used to separate a mixture of ions in a solution. In qualitative inorganic analysis, ions that form sparingly soluble precipitates with the same reagent are separated based on the differences in solubility products. For example, consider the separation of Cu(II) and Fe(II) ions by precipitation as insoluble sulfides. First, copper(II) sulfide is precipitated by the addition of acidic H2S, where the dissociation of H2S is suppressed. Adding H2S...
Extraction: Advanced Methods
Metal ions can be separated from one another by complexation with organic ligands–the chelating agent– to form uncharged chelates. Here, the chelating agent must contain hydrophobic groups and behave as a weak acid, losing a proton to bind with the metal. Since most organic ligands used in this process are insoluble or undergo oxidation in the aqueous phase, the chelating agent is initially added to the organic phase and extracted into the aqueous phase. The metal-ligand complex is formed in...
Effects of EDTA on End-Point Detection Methods
Different methods, such as visual observance of metal-ion indicators, spectroscopic techniques, and potentiometric methods, can determine the endpoint of an EDTA titration.
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
Controlled-Current Coulometry: Coulometric Titration
Coulometric titrations are a form of titrimetric analysis where the reagent is generated electrically, and its amount is evaluated based on current and generating time. The electron serves as the standard reagent. The procedure is similar to conventional titrations, such as endpoint detection.
The fundamental requirements for coulometric titrations are (1) 100% efficiency in the reagent-generating electrode reaction and (2) a stoichiometric and preferably rapid reaction between the generated...
The fundamental requirements for coulometric titrations are (1) 100% efficiency in the reagent-generating electrode reaction and (2) a stoichiometric and preferably rapid reaction between the generated...
Electrodeposition
Electrodeposition is a technique used to separate an analyte from interferents by electrochemical processes. Here, the analyte is a metal ion that can be deposited on an electrode immersed in the sample solution. The electrochemical setup consists of an anode and a cathode. When an electric current is applied to the setup, oxidation occurs at the anode. At the cathode, which consists of a large metal surface, metal ions undergo reduction and deposit onto the surface.
Electrodeposition can...
Electrodeposition can...