Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Capillary Electrophoresis: Instrumentation01:20

Capillary Electrophoresis: Instrumentation

Capillary electrophoresis instrumentation typically consists of several key components. A high-voltage power supply generates the electric field necessary for the separation by connecting to an anode (the positively charged electrode) and a cathode (the negatively charged electrode) located in buffer reservoirs at each end of the capillary tube. The system includes a sample vial, a fused silica capillary tube coated with polyimide for mechanical strength through which the sample components...
Voltammetric Techniques: Linear-Scan (E vs Time)01:12

Voltammetric Techniques: Linear-Scan (E vs Time)

Polarography is a classical voltammetric technique used to analyze electrochemical reactions. This method applies a linear potential sweep to a dropping mercury electrode (DME), and the resulting current is measured. A dropping mercury electrode is commonly used as the working electrode in polarography. It consists of a capillary tube filled with mercury, where the tiny droplet forms at the tip. This droplet continuously drops from the capillary, creating a new electrode surface for each...
Electrophoresis: Overview01:20

Electrophoresis: Overview

Electrophoresis is a powerful analytical separation technique that relies on the differential migration of charged species when subjected to an electric field. The core strength of electrophoresis lies in its ability to separate high-molecular-weight species in complex mixtures. It has found widespread use in biochemistry, molecular biology, and analytical chemistry, allowing the separation of compounds like amino acids, nucleotides, carbohydrates, and proteins with excellent resolution.
There...
High-Performance Liquid Chromatography: Types of Detectors01:15

High-Performance Liquid Chromatography: Types of Detectors

The role of the detectors in High-Performance Liquid Chromatography (HPLC) is to analyze the solutes as they exit from the chromatographic column. The detector recognizes the solute's property and generates corresponding electrical signals, which are converted into a readable graph of the detector's response versus elution time called a chromatogram at the computer. There are several types of HPLC detectors, each with its own advantages and limitations, depending on the analyte properties and...
Precipitation Titration: Endpoint Detection Methods01:19

Precipitation Titration: Endpoint Detection Methods

In argentometric precipitation titrations, endpoints can be detected visually by the Mohr, Volhard, and Fajans methods. In the Mohr method, adding a soluble chromate indicator gives an initial yellow color to the analyte solution. As the titrant is added, the first excess of silver ions forms a red silver chromate precipitate, marking the endpoint. The solution pH should be maintained at about 8 by adding solid CaCO3.
In the Volhard method, a standard excess of AgNO3 is first added to the...
Gas Chromatography: Types of Detectors-II01:19

Gas Chromatography: Types of Detectors-II

In gas chromatography, different detectors are employed to meet specific analytical needs. These detectors are often categorized based on their detection mechanisms and the types of compounds they are best suited to analyze. Thermal Conductivity Detectors (TCD), Flame Ionization Detectors (FID), and Electron Capture Detectors (ECD) represent common categories, each with unique operating principles and applications. However, beyond these, several other detectors are designed for more specialized...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Achievement of Target Gain Larger than Unity in an Inertial Fusion Experiment.

Physical review letters·2024
Same author

Lawson Criterion for Ignition Exceeded in an Inertial Fusion Experiment.

Physical review letters·2022
Same author

The transCampus Metabolic Training Programme Explores the Link of SARS-CoV-2 Virus to Metabolic Disease.

Hormone and metabolic research = Hormon- und Stoffwechselforschung = Hormones et metabolisme·2021
Same author

Guidelines for the management of diabetes in care homes during the Covid-19 pandemic.

Diabetic medicine : a journal of the British Diabetic Association·2020
Same author

Multidisciplinary healthcare teams' challenges and strategies in supporting people with type 1 diabetes to recover from disordered eating.

Diabetic medicine : a journal of the British Diabetic Association·2019
Same author

Factors influencing attendance at structured education for Type 1 diabetes in south London.

Diabetic medicine : a journal of the British Diabetic Association·2017

Related Experiment Video

Updated: Jun 28, 2026

Ultrasensitive Detection of Biomarkers by Using a Molecular Imprinting Based Capacitive Biosensor
08:22

Ultrasensitive Detection of Biomarkers by Using a Molecular Imprinting Based Capacitive Biosensor

Published on: February 16, 2018

A precision drop-fall detector for polarographic and electrocapillary work.

J B Craig1, D Hopkins, R A Howie

  • 1Department of Chemistry, University of Aberdeen, Meston Walk, Old Aberdeen, Scotland.

Talanta
|May 1, 1988
PubMed
Summary
This summary is machine-generated.

Researchers developed a precise detector for polarographic and electrocapillary studies. This instrument uses an AC bridge technique to measure capacitance changes during drop detachment, with drop-times recorded by a microcomputer.

More Related Videos

Dry Film Photoresist-based Electrochemical Microfluidic Biosensor Platform: Device Fabrication, On-chip Assay Preparation, and System Operation
13:42

Dry Film Photoresist-based Electrochemical Microfluidic Biosensor Platform: Device Fabrication, On-chip Assay Preparation, and System Operation

Published on: September 19, 2017

The Visual Colorimetric Detection of Multi-nucleotide Polymorphisms on a Pneumatic Droplet Manipulation Platform
10:01

The Visual Colorimetric Detection of Multi-nucleotide Polymorphisms on a Pneumatic Droplet Manipulation Platform

Published on: September 27, 2016

Related Experiment Videos

Last Updated: Jun 28, 2026

Ultrasensitive Detection of Biomarkers by Using a Molecular Imprinting Based Capacitive Biosensor
08:22

Ultrasensitive Detection of Biomarkers by Using a Molecular Imprinting Based Capacitive Biosensor

Published on: February 16, 2018

Dry Film Photoresist-based Electrochemical Microfluidic Biosensor Platform: Device Fabrication, On-chip Assay Preparation, and System Operation
13:42

Dry Film Photoresist-based Electrochemical Microfluidic Biosensor Platform: Device Fabrication, On-chip Assay Preparation, and System Operation

Published on: September 19, 2017

The Visual Colorimetric Detection of Multi-nucleotide Polymorphisms on a Pneumatic Droplet Manipulation Platform
10:01

The Visual Colorimetric Detection of Multi-nucleotide Polymorphisms on a Pneumatic Droplet Manipulation Platform

Published on: September 27, 2016

Area of Science:

  • Electrochemistry
  • Analytical Chemistry
  • Instrumentation

Background:

  • Polarography and electrocapillary measurements require precise detection methods.
  • Existing techniques may lack ruggedness or sensitivity for specific applications.

Purpose of the Study:

  • To describe the construction of a novel, rugged, and precise detector.
  • To enable accurate measurements in polarographic and electrocapillary work.

Main Methods:

  • Utilized an alternating current (a.c.) bridge technique.
  • Leveraged the significant capacitance change occurring upon drop detachment.
  • Integrated a laboratory microcomputer or counter/timer for drop-time recording.

Main Results:

  • Successfully constructed a rugged yet highly precise detector.
  • Demonstrated the utility of the a.c. bridge technique for detecting capacitance changes.
  • Enabled accurate timing and recording of drop-times.

Conclusions:

  • The developed detector offers a robust and precise solution for electroanalytical applications.
  • The a.c. bridge method is effective for monitoring drop-detachment events.
  • The integration with microcomputer systems enhances data acquisition capabilities.