NABTIT-a computer program for non-aqueous acid-base titration

O Budevsky1, T Zikolova, J Tencheva

  • 1Academy of Medicine, Faculty of Pharmacy, Ekz. Josif St. 15, Sofia-1000, Bulgaria.

Talanta
|November 1, 1988
PubMed

Related Concept Videos

Titration in Nonaqueous Solvents01:16

Titration in Nonaqueous Solvents

Most acid-base titrations are performed in an aqueous medium. In aqueous titrations, water competes with weaker acids or bases for proton donation or acceptance, leading to ambiguous endpoints in the titration curve. Water also affects the partial ionization of weak acids or bases. For example, water accepts a proton from acetic acid to form hydronium and acetate ions. The hydronium ion formed is a stronger acid than acetic acid, and the acetate ion is a stronger base than water. As a result,...
Conductometric Titrations: Strong Acid-Base and Weak Acid-Base Titrations01:29

Conductometric Titrations: Strong Acid-Base and Weak Acid-Base Titrations

In acid-base titrations, conductance measurements are utilized to detect the endpoint. This method is grounded on the fact that electrical conductance relies on the number and mobility of ions. For instance, consider titrating strong acid HCl with a strong NaOH base. Initially, the HCl in the conductivity vessel conducts electricity due to the presence of hydrogen ions and chloride ions. As NaOH is gradually added from the burette, the fast-moving hydrogen ions are replaced by slower-moving...
Titration of a Weak Acid with a Weak Base01:08

Titration of a Weak Acid with a Weak Base

Weak acids and bases do not undergo dissociation completely, and titrations between these two are rarely studied. When such studies are performed, say, for the titration of a weak acid with a weak base, the titration curve plots the change in pH as a function of the volume of base added. Take the titration of acetic acid with ammonia, for instance. During the titration, these two species form ammonium acetate and water, but the pH change is slow and gradual.
As a result, there is no simple...
Titration of a Weak Base with a Strong Acid01:20

Titration of a Weak Base with a Strong Acid

The titration curve of a weak base like ammonia with a strong acid like hydrochloric acid is the mirror image of the titration curve of a weak acid with a strong base.
Using the ICE table and substituting the Kb value, we calculate the initial pH of 50 mL of 0.1 M ammonia to be 11.11. Addition of 25 mL of 0.1 M hydrochloric acid to this solution of ammonia results in a buffer with an equal concentration of ammonia and ammonium ions. The pH of this buffer can be calculated by substituting these...
Conductometric Titrations: Strong Acid-Weak Base and Weak Acid-Strong Base Titrations01:22

Conductometric Titrations: Strong Acid-Weak Base and Weak Acid-Strong Base Titrations

When a weak acid such as acetic acid is titrated against a strong base like sodium hydroxide, the initial conductance is relatively low due to the weak dissociation of acetic acid. However, as sodium hydroxide is added to the solution, it reacts with the acetic acid to produce highly ionized sodium acetate, which causes an increase in conductance. Once all the acetic acid has been neutralized, any additional sodium hydroxide introduces fast-moving hydroxyl ions, leading to a sharper increase in...
Titration Calculations: Weak Acid - Strong Base03:55

Titration Calculations: Weak Acid - Strong Base

Calculating pH for Titration Solutions: Weak Acid/Strong Base
For the titration of 25.00 mL of 0.100 M CH3CO2H with 0.100 M NaOH, the reaction can be represented as: