Related Experiment Video
Updated: Jun 28, 2026

Post Column Derivatization Using Reaction Flow High Performance Liquid Chromatography Columns
Published on: April 26, 2016
Derivatization procedures for detection of prostaglandins in biological matrices by liquid
G M Beck1, D A Roston, B Jaselskis
1Searle Research and Development, Division of G. D. Searle and Co., 4901 Searle Parkway, Skokie, IL 60077, U.S.A.
Abstract:
Conventional reversed-phase HPLC conditions have been optimized for resolution of a mixture containing prostaglandins PGE(1), PGE(2), PGF(1alpha), and PGF(2alpha). Electroactive derivative-forming reagents, such as p-nitrobenzyloxyamine, 2-bromo-2'-nitroacetophenone, and 2,4-dinitrophenylhydrazine have been evaluated for use as precolumn reagents for forming prostaglandin derivatives. The results indicate that detection limits of 120 pg are achievable with amperometric detection. The utility of the procedures developed is illustrated by the detection of prostaglandins in human urine and plasma.
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
Electrophoresis: Overview
There...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Instrumentation
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...