Synthesis and characterization of some chromogenic crown ethers as potential optical sensors for potassium ions

S M Al-Amir1, D C Ashworth, R Narayanaswamy

  • 1Department of Instrumentation and Analytical Science, UMIST, P.O. Box 88, Manchester, England.

Talanta
|June 1, 1989
PubMed

Related Concept Videos

Crown Ethers02:36

Crown Ethers

Crown ethers are cyclic polyethers that contain multiple oxygen atoms, usually arranged in a regular pattern. The first crown ether was synthesized by Charles Pederson while working at DuPont in 1967. For this work, Pedersen was co-awarded the 1987 Nobel Prize in Chemistry. Crown ethers are named using the formula x-crown-y, where x is the total number of atoms in the ring and y is the number of ether oxygen atoms. The term 'crown' refers to the crown-like shape that these ether molecules take.
Flame Photometry: Lab01:16

Flame Photometry: Lab

In a flame photometer, when a solution like potassium chloride is aspirated into the flame, the solvent evaporates, leaving behind dehydrated salt. This salt dissociates into free gaseous atoms in their ground state. Some of these atoms absorb energy from the flame, leading to their excitation. The excited atoms return to the ground state, emitting photons at characteristic wavelengths. Because only electronic transitions are involved, the resulting emission lines are very narrow. The intensity...
Qualitative Analysis03:46

Qualitative Analysis

For solutions containing mixtures of different cations, the identity of each cation can be determined by qualitative analysis. This technique involves a series of selective precipitations with different chemical reagents, each reaction producing a characteristic precipitate for a specific group of cations. Metal ions within a group are further separated by varying the pH, heating the mixture to redissolve a precipitate, or adding other reagents to form complex ions.
For instance, group IV...
Potentiometry: Membrane Electrodes01:15

Potentiometry: Membrane Electrodes

Membrane electrodes, also known as p-ion electrodes, use membranes that selectively interact with free analyte ions, generating a potential difference across the membrane. The resulting membrane potential, known as the asymmetry potential, is not zero even when analyte concentrations on both sides of the membrane are equal. The membrane's response is typically not selective to a single analyte but proportional to the concentration of all ions in the sample solution capable of interacting at the...
Photoluminescence: Applications01:14

Photoluminescence: Applications

Photoluminescence offers a wide range of applications due to its inherent sensitivity and selectivity. This technique allows for both direct and indirect analyses of the analyte. Direct quantitative analysis is possible when the analyte exhibits a favorable quantum yield for fluorescence or phosphorescence. However, an indirect analysis may be feasible if the analyte is not fluorescent or phosphorescent, or if the quantum yield is unfavorable. Indirect methods include reacting the analyte with...