Determination of trace amounts of manganese in nickel by fourth-derivative spectrophotometry
Related Experiment Video
Updated: Jun 28, 2026

Quantification of Metal Leaching in Immobilized Metal Affinity Chromatography
Published on: January 17, 2020
1Department of Analytical Chemistry, Technical University, Warsaw, Poland.
Abstract:
Fourth-derivative absorption spectra were used to determine trace amounts of manganese in nickel salts. Optimum conditions for the oxidation of microgram amounts of Mn(II) to MnO(-)(4) in the presence of large amounts of nickel were established. Fourth-derivative spectra provided good sensitivity and selectivity for this determination. Attention has been paid to the effect of instrumental parameters on the results obtained. Limitations of the peak-to-trough and zero-crossing measurement techniques have been examined. Manganese (1 x 10(-3)-2 x 10(-5)%) in nickel salts (nitrate, sulphate and chloride) and in nickel powder was determined with good precision and accuracy.
Related Concept Videos
Precipitation Gravimetry
In determining nickel by gravimetric analysis, a precipitant of ethanolic dimethylglyoxime is added to a hot nickel salt solution. This is quickly followed by the dropwise addition of dilute ammonia solution until precipitation occurs. A...
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...