Related Experiment Video
Updated: Jun 28, 2026

Extending the Lifespan of Soluble Lead Flow Batteries with a Sodium Acetate Additive
Published on: January 7, 2019
Electrodeposition on pyrolytic graphite platforms for electrothermal atomic-absorption spectroscopic determination of
1Department of Chemistry, Mahidol University, Bangkok 10400 Thailand.
Abstract:
A technique for the determination of labile Pb in sea-water has been developed which uses co-deposition with mercury on 6-14-mg pyrolytic graphite platforms, followed by electrothermal atomization of the deposit. Optimization of the applied voltage, pH and sodium chloride concentration with respect to the deposition efficiency yielded a detection limit of 0.15 mug/l. Pb for 120-sec depositions with a single platform. As the amount of deposit increases linearly with deposition time up to 5 min and the simultaneous use of two platforms increases the analytical signal by a factor of 1.73, a further improvement is possible. Near-shore sea-water and estuarine water samples containing lead in the concentration range 0.4-1.3 mug/l. were analysed with an RSD better than 10%. Background correction was not required as the technique eliminates spectral interferences due to molecular absorption.
Related Concept Videos
Electrodeposition
Electrodeposition can...
Electrogravimetric Analysis: Overview
To test the completeness of the...
Atomic Emission Spectroscopy: Lab
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...