Relative response ratios for dual-isotope measurements via coelution and GC/MS
1Department of Chemistry, Seattle University, Seattle, Washington 98122, U.S.A.
Abstract:
Dual-isotope internal standard measurements by GC/MS which mimic isotope dilution may suffer from non-linear response relations, irreproducibilities or unduly large uncertainties because of variations in ionization efficiences for the respective isotopic forms in the MS source. Such variations may sometimes be avoided via extensive pretreatments, high resolution GC separations and careful control of instrumental parameters. However, an alternative approach is feasible which instead exploits advantages of decreasing GC resolution. By forcing both forms of each analyte to coelute, their relative ionization efficiencies in the MS source should be nearly constant, thereby effectively allowing for constant relative sensitivities over several orders of magnitude in concentration. Thus, constant relative response ratios, required for internal standard calculations, may be attained as a consequence of dramatically lowered GC resolution. Coelution results described herein show linear relative sensitivity relations over much broader ranges than observed for corresponding conventional calibrations with separated components. Coelution methods for dual-isotope GC/MS determinations are compatible with internal standard calculations and thereby offer a powerful alternative to the conventional approach of requiring expensive and labor-intensive additional pretreatments and separations to assure resolution of measured eluates.
More Related Videos
09:26Cellular Lipid Extraction for Targeted Stable Isotope Dilution Liquid Chromatography-Mass Spectrometry Analysis
Published on: November 17, 2011
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Related Concept Videos
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Tandem Mass Spectrometry
Mass Spectrometry: Isotope Effect
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences