Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Gas Chromatography: Types of Detectors-II01:19

Gas Chromatography: Types of Detectors-II

In gas chromatography, different detectors are employed to meet specific analytical needs. These detectors are often categorized based on their detection mechanisms and the types of compounds they are best suited to analyze. Thermal Conductivity Detectors (TCD), Flame Ionization Detectors (FID), and Electron Capture Detectors (ECD) represent common categories, each with unique operating principles and applications. However, beyond these, several other detectors are designed for more specialized...
Photoreceptors and Visual Pathways01:22

Photoreceptors and Visual Pathways

At the molecular level, visual signals trigger transformations in photopigment molecules, resulting in changes in the photoreceptor cell's membrane potential. The photon's energy level is denoted by its wavelength, with each specific wavelength of visible light associated with a distinct color. The spectral range of visible light, classified as electromagnetic radiation, spans from 380 to 720 nm. Electromagnetic radiation wavelengths exceeding 720 nm fall under the infrared category, whereas...
Determination of Crystal Structures01:29

Determination of Crystal Structures

In the late 1800s, the revelation that light extended beyond visible wavelengths led to the discovery of X-rays by Wilhelm Roentgen. Recognized as high-energy electromagnetic radiation with short wavelengths, X-rays prompted exploration into their interaction with crystals. Max von Laue proposed in 1912 that the periodic arrangement of atoms, ions, or molecules in crystals would cause them to diffract X-rays, a hypothesis confirmed through experiments with copper sulfate and zinc sulfide...
UV–Vis Spectrometers01:14

UV–Vis Spectrometers

The absorbance of UV and visible (UV–visible) radiations is measured using a UV–visible spectrophotometer. Deuterium lamps, which emit UV radiation, and tungsten lamps, which produce radiation in the visible region, are used as light sources in UV–visible spectrophotometers. A monochromator or prism is used for diffraction grating, i.e., to split the incoming radiation into different wavelengths. A system of slits is used to focus the desired wavelength on the sample cell. Samples for...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Capillary electrophoretic determination of different classes of organic ions by potentiometric detection with coated-wire ion-selective electrodes.

Analytical chemistry·2011
Same author

Potentiometric detection of alkali and alkaline Earth metal cations in capillary electrophoresis with simplified electrode alignment and enhanced separation and sensitivity.

Analytical chemistry·2011
Same author

Recent developments in detection methods for microfabricated analytical devices.

Lab on a chip·2004
Same author

Rapid chiral on-chip separation with simplified amperometric detection.

Journal of chromatography. A·2001
Same author

A two-electrode configuration for simplified amperometric detection in a microfabricated electrophoretic separation device.

The Analyst·2001
Same author

Amperometric sensing of ethylene oxide in the gas phase.

Analytical chemistry·2000

Related Experiment Video

Updated: Jun 28, 2026

Enhanced Electron Injection and Exciton Confinement for Pure Blue Quantum-Dot Light-Emitting Diodes by Introducing Partially Oxidized Aluminum Cathode
10:41

Enhanced Electron Injection and Exciton Confinement for Pure Blue Quantum-Dot Light-Emitting Diodes by Introducing Partially Oxidized Aluminum Cathode

Published on: May 31, 2018

A photometric detector based on a blue light-emitting diode.

P C Hauser1, D W Chiang

  • 1The University of Auckland, Department of Chemistry, Private Bag 92019, Auckland, New Zealand.

Talanta
|August 1, 1993
PubMed
Summary

Blue light-emitting diodes show promise as cost-effective radiation sources for molecular absorption spectroscopy. A novel transducer demonstrated accurate absorbance readings for common elements and in flow-injection analysis.

More Related Videos

Light Spot-Based Assay for Analysis of Drosophila Larval Phototaxis
07:16

Light Spot-Based Assay for Analysis of Drosophila Larval Phototaxis

Published on: September 27, 2019

Local Field Fluorescence Microscopy: Imaging Cellular Signals in Intact Hearts
10:33

Local Field Fluorescence Microscopy: Imaging Cellular Signals in Intact Hearts

Published on: March 8, 2017

Related Experiment Videos

Last Updated: Jun 28, 2026

Enhanced Electron Injection and Exciton Confinement for Pure Blue Quantum-Dot Light-Emitting Diodes by Introducing Partially Oxidized Aluminum Cathode
10:41

Enhanced Electron Injection and Exciton Confinement for Pure Blue Quantum-Dot Light-Emitting Diodes by Introducing Partially Oxidized Aluminum Cathode

Published on: May 31, 2018

Light Spot-Based Assay for Analysis of Drosophila Larval Phototaxis
07:16

Light Spot-Based Assay for Analysis of Drosophila Larval Phototaxis

Published on: September 27, 2019

Local Field Fluorescence Microscopy: Imaging Cellular Signals in Intact Hearts
10:33

Local Field Fluorescence Microscopy: Imaging Cellular Signals in Intact Hearts

Published on: March 8, 2017

Area of Science:

  • Analytical Chemistry
  • Spectroscopy
  • Optoelectronics

Background:

  • Conventional molecular absorption spectroscopy often relies on expensive and complex radiation sources.
  • The development of alternative, cost-effective light sources is crucial for broader accessibility in analytical techniques.

Purpose of the Study:

  • To evaluate the suitability of blue light-emitting diodes (LEDs) as radiation sources for molecular absorption spectroscopy.
  • To develop and test a novel transducer for direct absorbance measurements using blue LEDs.

Main Methods:

  • Investigated electronic and spectral characteristics of blue LEDs for spectroscopic applications.
  • Designed a transducer incorporating a blue LED, photodiode, and logarithmic converter for direct absorbance readings.
  • Tested the transducer's performance in standard spectrophotometric analyses for Cr, Mn, Zn, Fe, and Cl.
  • Evaluated the transducer's utility as a detector in flow-injection analysis.

Main Results:

  • Blue LEDs were found suitable as radiation sources, with electronic and spectral properties discussed.
  • The developed transducer provided direct absorbance readings.
  • The device showed comparable performance to conventional methods for analyzing Cr, Mn, Zn, Fe, and Cl.
  • The transducer proved effective as a detector in flow-injection analysis.

Conclusions:

  • Blue LEDs are a viable and potentially economical alternative radiation source for molecular absorption spectroscopy.
  • The developed LED-based transducer offers a simple and effective solution for direct absorbance measurements.
  • This technology has potential applications in both standard spectrophotometry and flow-injection analysis.