Determination of ascorbic acid in pharmaceutical preparations by near infrared reflectance spectroscopy

M Blanco1, J Coello, H Iturriaga

  • 1Departamento de Química, Unidad de Química Analítica, Universidad Autónoma de Barcelona, E-08193 Bellaterra, Barcelona, Spain.

Talanta
|November 1, 1993
PubMed

Related Concept Videos

IR and UV–Vis Spectroscopy of Carboxylic Acids01:28

IR and UV–Vis Spectroscopy of Carboxylic Acids

In IR spectroscopy of carboxylic acids, the C=O bond shows a characteristic band between 1710 and 1760 cm⁻¹, and the O–H bond exhibits a broad band between 2500 and 3300 cm⁻¹.
However, the stretching absorptions for the C=O bond vary depending on the structure of carboxylic acids. The C=O bond of the free carboxylic acids shows a higher stretching frequency, 1760 cm−1, while H-bonded carboxylic acids (dimers) exhibit stretching absorptions at a lower frequency, 1710 cm−1. The C=O bond of the...
Atomic Absorption Spectroscopy: Lab01:21

Atomic Absorption Spectroscopy: Lab

For AAS measurements, samples must be introduced as clear solutions, often requiring extensive preliminary treatment to dissolve materials like soils, animal tissues, and minerals. Common methods for sample preparation include treatment with hot mineral acids, wet ashing, combustion in closed containers, high-temperature ashing, or fusion with reagents.
 Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview01:13

Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview

Attenuated total reflectance (ATR) infrared spectroscopy is a powerful analytical technique used to study the composition of materials. It is widely employed in chemistry, materials science, forensic science, and other fields where sample characterization is required. ATR has several advantages over traditional transmission IR spectroscopy, including the requirement of little to no sample preparation and the ability to analyze a wide range of samples.
The ATR process begins by directing a beam...
Spectroscopy of Carboxylic Acid Derivatives01:26

Spectroscopy of Carboxylic Acid Derivatives

Infrared spectroscopy is primarily used to determine the types of bonds and functional groups. In carboxylic acid derivatives, a typical carbonyl bond absorption is observed around 1650–1850 cm−1. For esters, the absorption is recorded at around 1740 cm−1, while acid halides show the absorption at about 1800 cm−1. Another acid derivative, the acid anhydrides, exhibit two carbonyl absorption around 1760 cm−1 and 1820 cm−1, arising from the symmetrical and unsymmetrical carbonyl vibration.
In the...