Comparison of four microwave digestion methods for the determination of selenium in fish tissue by using hydride
1Department of Chemistry, National University of Singapore, 10 Kent Ridge Crescent, Singapore 0511, Republic of Singapore.
Abstract:
Four microwave digestion methods of fish tissue for selenium determination by hydride generation atomic absorption spectrometry were compared, in which potassium hexacyanoferrate(III) was chosen as a masking agent for eliminating matrix interferences. The results showed that the methods employing HNO(3)/H(2)O(2), HNO(3)/K(2)S(2)O(8)/H(2)O(2) and HNO(3)/H(3)PO(4)/H(2)O(2) digestion media were unreliable. However, the decomposition using the digestion media of HNO(3)/H(2)SO(4)/H(2)O(2) enabled adequate digestion of fish tissue and retention of selenium in a state amenable for determination. Therefore, the digestion procedures with HNO(3)/H(2)SO(4)/H(2)O(2) media are proposed for the determination of selenium in fish tissue by hydride generation atomic absorption spectrometry. The recoveries of the spiked samples investigated ranged from 90 to 102%. The result obtained from analyzing the NIES CRM No. 6 mussel was in good agreement with the reference value (reference value: 1.5 mug/g; found: 1.45 +/- 0.05 mug/g). The limit of detection for selenium was 0.03 mug/g dry mass for a 100 mg sample. The contents of selenium in local fish species investigated ranged from 0.49 to 2.90 mug/g, and the relative standard deviation for the determination of selenium was less than 8%.
More Related Videos
06:53Preparation of Food Samples Using Homogenization and Microwave-Assisted Wet Acid Digestion for Multi-Element Determination with ICP-MS
Published on: December 22, 2023
06:00Biological Samples Preparation for Speciation at Cryogenic Temperature using High-Resolution X-Ray Absorption Spectroscopy
Published on: May 27, 2022
Related Concept Videos
Atomic Absorption Spectroscopy: Atomization Methods
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Sample Preparation for Analysis: Advanced Techniques
Acid digestion with strong acids is commonly used to dissolve inorganic materials that are insoluble (do not dissolve) in water. This method can be useful for...
Atomic Emission Spectroscopy: Lab
Atomic Emission Spectroscopy: Overview