Related Experiment Video
Updated: Jun 28, 2026

Clean Sampling and Analysis of River and Estuarine Waters for Trace Metal Studies
Published on: July 1, 2016
Determination of dissolved selenium(VI) in freshwater
1Uppsala University, Department of Analytical Chemistry, P.O. Box 531, S-751 21 Uppsala, Sweden.
Abstract:
A procedure is proposed for the determination of selenate in freshwaters with a high content of dissolved organic material. After passage through an XAD-8 column, selenate is collected on a strong anion exchanger and subsequently eluted with hydrochloric acid. Following conversion into the tetravalent state, selenium is determined using atomic absorption spectrometry after hydride generation and preconcentration in a cold trap system. The two-column procedure effectively separates selenium(VI) from possible organic interferents and allows quantification at the low ng/l. level. Results from the investigation of waters from lakes and streams indicate that selenium(IV) and (VI) may constitute a very small part of total dissolved selenium.