Related Experiment Video
Updated: Jun 28, 2026

Accumulation and Analysis of Cuprous Ions in a Copper Sulfate Plating Solution
Published on: March 20, 2019
Spectrophotometric determination of tin in copper-based alloys using pyrocatechol violet
A C Costa1, L S Teixeira, S L Ferreira
1Universidade Federal da Bahia, Instituto de Quimica, Salvador, Bahia 40170-290, Brazil.
Abstract:
In the present paper, a new procedure using Pyrocatechol Violet (PCV) for the determination of tin in copper-based alloys is proposed. The use of HEDTA as masking agent allowed tin to be determined in the presence of large amounts of copper, without any separation procedure. The method is more selective than previous methods. Cetyltrimethylammonium bromide (CTAB) and Tween-20 are used to increase the stability of the system. The method can be applied directly to an acidic solution of Sn(IV) in the range 2.0-60.0 mug with a final volume of 50 ml. The pH is adjusted to 2.0 +/- 0.2 with glycine buffer and, after 30 min, the absorbance is measured at 660 nm. Al(III), Cd(II), Co(II), Mg(II), Ca(II), Mn(II), Ni(II) and Pb(II) do not interfere at the 500 mg level; 20 000 mug of Cu(II) and 400 mug of NaCl can be present. The interference at 100 mug of Fe(III) can be masked with ascorbic acid. Bi(III), Sb(V), Ti(IV), Mo(VI), EDTA, tartrate, citrate and iodide interfere. The proposed method was used for tin determination in several copper-based alloys and a comparison of the analytical results with certified values indicates that the procedure provides accurate and precise results.
More Related Videos
09:51TD-DFT Guided Advanced E-Eye Sensing Technique for On-site Quantification of Fe, Cr, F, and As in the Environmental, Biological, and Food Samples
Published on: September 19, 2025
11:38Quantifying the Binding Interactions Between Cu(II) and Peptide Residues in the Presence and Absence of Chromophores
Published on: April 5, 2022
Related Concept Videos
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
Redox Titration: Iodimetry and Iodometry
Precipitation Titration Curve: Analysis
Precipitation Titration: Overview
A precipitation titration curve demonstrates the change in concentration of the titrant or analyte upon adding the...
Voltammetric Techniques: Cyclic Voltammetry