Sulphate determination after its reduction to hydrogen sulphide and volatile separation by molecular absorption

Talanta
|September 1, 1996
PubMed

Related Concept Videos

Volatilization01:10

Volatilization

Volatilization gravimetry is an analytical technique that measures the mass lost due to the volatilization of the substance. This technique is used to estimate the amount of volatile material in a sample. To perform this method, heat a known amount of the sample to a high temperature in a crucible or other suitable vessel. The volatile substance in the sample evaporates, and the vapor is completely expelled from the crucible either by heating the sample or bubbling a stream of inert gas through...
Preparation and Reactions of Sulfides02:26

Preparation and Reactions of Sulfides

Sulfides are the sulfur analog of ethers, just as thiols are the sulfur analog of alcohol. Like ethers, sulfides also consist of two hydrocarbon groups bonded to the central sulfur atom. Depending upon the type of groups present, sulfides can be symmetrical or asymmetrical. Symmetrical sulfides can be prepared via an SN2 reaction between 2 equivalents of an alkyl halide and one equivalent of sodium sulfide.
Preparation and Reactions of Thiols02:33

Preparation and Reactions of Thiols

Thiols are prepared using the hydrosulfide anion as a nucleophile in a nucleophilic substitution reaction with alkyl halides. For instance, bromobutane reacts with sodium hydrosulfide to give butanethiol.
Atomic Absorption Spectroscopy: Lab01:21

Atomic Absorption Spectroscopy: Lab

For AAS measurements, samples must be introduced as clear solutions, often requiring extensive preliminary treatment to dissolve materials like soils, animal tissues, and minerals. Common methods for sample preparation include treatment with hot mineral acids, wet ashing, combustion in closed containers, high-temperature ashing, or fusion with reagents.
 Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Atomic Absorption Spectroscopy: Atomization Methods01:25

Atomic Absorption Spectroscopy: Atomization Methods

Atomic Absorption Spectroscopy (AAS) atomizes samples through flame atomization or electrothermal atomization. Flame atomization typically involves a nebulizer and spray chamber assembly to combine the sample with a fuel–oxidant mixture, creating a fine aerosol mist that enters a burner. Typically, the fuel and oxidant are combined in an approximately stoichiometric ratio. However, for atoms that are easily oxidized, a fuel-rich mixture may be more advantageous. Only about 5% of the aerosol...
UV–Vis Spectrometers01:14

UV–Vis Spectrometers

The absorbance of UV and visible (UV–visible) radiations is measured using a UV–visible spectrophotometer. Deuterium lamps, which emit UV radiation, and tungsten lamps, which produce radiation in the visible region, are used as light sources in UV–visible spectrophotometers. A monochromator or prism is used for diffraction grating, i.e., to split the incoming radiation into different wavelengths. A system of slits is used to focus the desired wavelength on the sample cell. Samples for...