Calibration procedure for solid phase microextraction-gas chromatographic analysis of organic vapours in air
1Department of Analytical Chemistry, Chemical Faculty, Technical University of Gdańsk, 90-952 Gdańsk, Poland.
Abstract:
A calibration procedure for solid phase microextraction-gas chromatographic (SPME-GC) analysis of organic vapours in air was described in which GC detector (MS in this case) signal is directly related to concentration of analytes of interest sampled by SPME. Gaseous standard mixtures used for the calibration were generated by means of a home-made permeation-type apparatus described elsewhere, W. Janicki et al., Chem. Anal., 38 (1993) 423 and modified to permit easy sampling of analytes on an SPME fibre. To establish sampling parameters, times for equilibrium partitioning of five selected organic compounds (carbon tetrachloride, toluene, chlorobenzene, p-xylene, n-decane) between gaseous mixtures and the fibre (fused silica fibre coated with 100 mum polydimethylsiloxane) were determined. For 10 min sampling time, the detector response and hence amount sampled on the fibre were linear functions of analytes concentration in a gaseous sample.
More Related Videos
05:31Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
05:29Profiling Volatile Compounds in Blackcurrant Fruit using Headspace Solid-Phase Microextraction Coupled to Gas Chromatography-Mass Spectrometry
Published on: June 9, 2021
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Sample Preparation for Analysis: Overview
Bulk or large solid samples are typically reduced in size using grinding, crushing, or milling techniques to increase the...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...