Related Experiment Video
Updated: Jun 28, 2026

Dynamic Electrochemical Measurement of Chloride Ions
Published on: February 5, 2016
Carbonate ion selective electrodes with trifluoroacetophenone derivatives in potentiometric clinical analyser
M Maj-Zurawska1, T Sokalski, J Ostaszewska
1University of Warsaw, Department of Chemistry, 02 093 Warszawa, ul. Pasteura 1, Poland.
Abstract:
Properties of six derivatives of 1-trifluoroacetylbenzene: [4-(n-butyl)- (1), 4-(n-hexadecyl)- (2), 4-dodecyloxy- (3), 4-(n-dodecylsulfonyl)- (4), N,N-dioctyl-4-trifluoroacetylbenzamide (5), octyl-p-trifluoroacetylbenzoate (6)] as neutral carriers for carbonate ion were examined and compared. The sensitivity towards carbonate ion was for (3) pH dependent. This eliminates (3) from practical applications in clinical analysis. When measuring CO(3)(2-) within the physiological range of human blood using as carriers compounds 1 and 2 the interference of chloride must be taken into account. In the case of carriers 4, 5, 6 this effect is negligible. Electrodes with membranes containing as carriers 2, 4, 5 and 6 were tested in an automatic potentiometric clinical analyser Microlyte 6, KONE. To avoid contamination by atmospheric CO(2) of three aqueous standards (TES, NaCl, NaHCO(3)), pH was adjusted by coulomeric generation of H(+) or OH(-) in a system devoid of carbon dioxide. Recovery of HCO(3)(-) calculated from measured CO(3)(2-) and pH, was investigated in a series of aqueous solutions and spiked bovine serum samples. The correlation between added and recovered concentration of HCO(3)(-) was linear with the intercept close to 0 and slope equal to 1 in aqueous solutions for all ligands and in bovine serum samples only in the case of ligand (2).
More Related Videos
Related Concept Videos
Potentiometry: Membrane Electrodes
Potentiometry: Types of Electrodes
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
Potentiometric Titration: Overview
Controlled-Potential Coulometry: Electrolytic Methods
The chosen potential ensures...
Electrodes: Overview
There are two main types of electrodes in electrochemical cells. The first type, known as the working or indicator electrode, has a potential that is sensitive to the analyte's concentration and reacts to changes in the...
Potentiometry: Overview