Study of the determination of acetylcholine after enzymatic hydrolysis by triangle programmed coulometric flow

R E Gyurcsányi1, Z Fehér, G Nagy

  • 1Institute of General and Analytical Chemistry, Technical University of Budapest, Gellért tér 4, H-1111 Budapest, Hungary.

Talanta
|October 31, 2008
PubMed

Related Concept Videos

Controlled-Current Coulometry: Coulometric Titration01:18

Controlled-Current Coulometry: Coulometric Titration

Coulometric titrations are a form of titrimetric analysis where the reagent is generated electrically, and its amount is evaluated based on current and generating time. The electron serves as the standard reagent. The procedure is similar to conventional titrations, such as endpoint detection.
The fundamental requirements for coulometric titrations are (1) 100% efficiency in the reagent-generating electrode reaction and (2) a stoichiometric and preferably rapid reaction between the generated...
Solution Composition During Acid/Base Titrations01:17

Solution Composition During Acid/Base Titrations

The titration of a weak acid with a strong base results in the formation of water and the conjugate base of the acid. For instance, titrating acetic acid with sodium hydroxide leads to the formation of water and sodium acetate. A solution of acetic acid and sodium acetate constitutes a buffer whose relative concentration at different stages of the titration is indicated by the α values, which represent percentages of the weak acid and its conjugate base.
The α0 and α1 values represent the...
Controlled-Current Coulometry: Overview01:27

Controlled-Current Coulometry: Overview

Controlled current coulometry, also known as amperostatic coulometry, is a technique used in electrochemical analysis to measure the quantity of a substance through the controlled passage of current. It involves the application of a constant current to an electrochemical cell containing the analyte of interest. As the current flows through the cell, the analyte undergoes a redox reaction at the electrode surface, resulting in a charge transfer. By monitoring the time required for a certain...
Cholinergic Neurons: Neurotransmission01:23

Cholinergic Neurons: Neurotransmission

Cholinergic neurotransmission involves the synthesis and the release of acetylcholine (ACh) in order to transmit nerve impulses across the synapse. The process begins with the synthesis of acetyl CoA, a precursor for ACh, from ATP, acetate, and coenzyme A in the mitochondria. Choline, another vital precursor, is transported inside the neuron through choline transporters, including high-affinity choline transporter CHT1, low-affinity choline transporter CTL1, and lower-affinity choline...
Acid-Base Titration Curves02:23

Acid-Base Titration Curves

A titration curve is a plot of some solution property versus the amount of added titrant. For acid-base titrations, solution pH is a useful property to monitor because it varies predictably with the solution composition and, therefore, may be used to monitor the titration’s progress and detect its endpoint. Acid-base titration can be performed with a strong acid and a strong base, a strong acid and a weak base, or a strong base and a weak acid.
For a titration carried out for 25.00 mL of 0.100...
Titration Calculations: Weak Acid - Strong Base03:55

Titration Calculations: Weak Acid - Strong Base

Calculating pH for Titration Solutions: Weak Acid/Strong Base
For the titration of 25.00 mL of 0.100 M CH3CO2H with 0.100 M NaOH, the reaction can be represented as: