Headspace solid phase microextraction (HSSPME) for the determination of volatile and semivolatile pollutants in soils
1Departamento de Quimica Analitica Nutricion y Bromatologia, Facultad de Quimica, Universidad de Santiago de Compostela, E-15706 Santiago de Compostela, Spain.
Abstract:
We have investigated the use of headspace solid phase microextraction (HSSPME) as a sample concentration and preparation technique for the analysis of volatile and semivolatile pollutants in soil samples. Soil samples were suspended in solvent and the SPME fibre suspended in the headspace above the slurry. Finally, the fibre was desorbed in the Gas Chromatograph (GC) injection port and the analysis of the samples was carried out. Since the transfer of contaminants from the soil to the SPME fibre involves four separate phases (soil-solvent-headspace and fibre coating), parameters affecting the distribution of the analytes were investigated. Using a well-aged artificially spiked garden soil, different solvents (both organic and aqueous) were used to enhance the release of the contaminants from the solid matrix to the headspace. It was found that simple addition of water is adequate for the purpose of analysing the target volatile organic chemicals (VOCs) in soil. The addition of 1 ml of water to 1 g of soil yielded maximum response. Without water addition, the target VOCs were almost not released from the matrix and a poor response was observed. The effect of headspace volume on response as well as the addition of salt were also investigated. Comparison studies between conventional static headspace (HS) at high temperature (95 degrees C) and the new technology HSSPME at room temperature ( approximately 20 degrees C) were performed. The results obtained with both techniques were in good agreement. HSSPME precision and linearity were found to be better than automated headspace method and HSSPME also produced a significant enhancement in response. The detection and quantification limits for the target VOCs in soils were in the sub-ng g(-1) level. Finally, we tried to extend the applicability of the method to the analysis of semivolatiles. For these studies, two natural soils contaminated with diesel fuel and wood preservative, as well as a standard urban dust contaminated with polyaromatic hydrocarbons (PAHs) were tested. Discrimination in the response for the heaviest compounds studied was clearly observed, due to the poor partition in the headspace and to the slow kinetics of all the processes involved in HSSPME.
Related Concept Videos
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Sampling Methods: Sample Types
Solid samples include a variety of substances, such as sediments from water bodies, soil, metals, and biological tissues. Two standard methods for extracting sediments from water bodies are grab sampling and piston coring. Grab sampling involves using a device to collect a discrete sediment sample from the bottom of a water body with minimal disturbance. Grab samples do not always represent the entire area due to...
Sample Preparation for Analysis: Overview
Bulk or large solid samples are typically reduced in size using grinding, crushing, or milling techniques to increase the...
Volatilization