Flow injection potentiometry for enzymatic assay of cholesterol with a tungsten electrode sensor
M Situmorang1, P W Alexander, D B Hibbert
1Department of Analytical Chemistry, University of New South Wales, Sydney, NSW 2052, Australia.
Abstract:
Flow injection potentiometry (FIP) for the enzymatic determination of cholesterol is reported. The assay utilises a combination of three enzymes: cholesterol esterase (CE), cholesterol oxidase (COD) and peroxidase (POD). The method is developed by the use of a tungsten wire electrode as a sensor vs. Ag/AgCl in conjunction with a redox mediator ferrocyanide. CE converts esterified cholesterol to free cholesterol, which is then oxidised by COD with hydrogen peroxide as product. Ferrocyanide is converted to ferricyanide by hydrogen peroxide, catalysed by POD, and the tungsten electrode responds to the ratio of ferricyanide to ferrocyanide. Flow injection potentiometry gave well-defined peaks for cholesterol samples with a fast response (30 s). Linear calibration was obtained from 0.05 to 3.0 mM cholesterol, with a slope of 60.2 mV/decade change in cholesterol concentration, and detection limit 0.01 mM cholesterol (S/N=3). Repeatability was 3% (CV). Interferences from commonly found species were shown to be negligible. The sensor cell is simple to construct, and it was free from surface contamination problems over long periods of use. The application of the sensor for the determination of serum cholesterol was demonstrated.
More Related Videos
13:42Dry Film Photoresist-based Electrochemical Microfluidic Biosensor Platform: Device Fabrication, On-chip Assay Preparation, and System Operation
Published on: September 19, 2017
12:15Single Liposome Measurements for the Study of Proton-Pumping Membrane Enzymes Using Electrochemistry and Fluorescent Microscopy
Published on: February 21, 2019
Related Concept Videos
Controlled-Potential Coulometry: Electrolytic Methods
The chosen potential ensures...
Potentiometry: Membrane Electrodes
Potentiometry: Types of Electrodes
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
Potentiometry: Overview
Interfacial Electrochemical Methods: Overview
Electrodeposition
Electrodeposition can...