Related Experiment Video
Updated: Jun 28, 2026

Preparation of Food Samples Using Homogenization and Microwave-Assisted Wet Acid Digestion for Multi-Element Determination with ICP-MS
Published on: December 22, 2023
Multielement analysis of coal by ICP techniques using solution nebulization and laser ablation
I Rodushkin1, M D Axelsson, E Burman
1SGAB Analytica, Luleå University of Technology, S-971 87 Luleå, Sweden.
Abstract:
The combination of inductively coupled plasma atomic emission spectrometry and high resolution inductively coupled plasma mass spectrometry for the determination of 70 elements in coal were studied. Four microwave-assisted digestion procedures with different dissolution mixtures (nitric and hydrofluoric acids, aqua regia and hydrogen peroxide), lithium metaborate fusion with and without previous sample ashing as well as direct sampling by laser ablation (LA) have been tested. Examples of spectral interferences are given and different correction procedures are discussed. Detection limits in the low ng g(-1) range were obtained for most of the elements investigated by using high-purity reagents and by taking special care to prevent sample contamination during preparation. The precision was assessed from replicate analysis (including sample preparation) of coal samples and was found to be, as average values far all elements, 4-5% RSD and 10-15% RSD for procedures including sample digestion and LA sampling, respectively. The accuracy of the overall analytical procedures was estimated by analysis of certified reference materials and of a coal sample obtained from the Interlab Trace round robin test. Among the dissolution mixtures tested, the combination of nitric and hydrofluoric acids with hydrogen peroxide provide the best agreement with certified, recommended, literature-compiled or consensus values, though fusion is necessary to obtain quantitative recoveries for Si, Cr, Hf, W, Zr, Y. In general, results obtained by LA fall within +/-20% of those obtained after digestion.
Related Concept Videos
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Atomic Emission Spectroscopy: Lab
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
Atomic Emission Spectroscopy: Instrumentation

