Related Experiment Video
Updated: Jun 28, 2026

Clean Sampling and Analysis of River and Estuarine Waters for Trace Metal Studies
Published on: July 1, 2016
Microscale extraction of perchlorate in drinking water with low level detection by electrospray-mass spectrometry
M L Magnuson1, E T Urbansky, C A Kelty
1US Environmental Protection Agency, Office of Research and Development, National Risk Management Research Laboratory, Water Supply and Water Resources Division, Treatment Technology Evaluation Branch, 26 W Martin Luther King Drive, Cincinnati, OH 45268 USA.
Abstract:
Improper treatment and disposal of perchlorate can be an environmental hazard in regions where solid rocket motors are used, tested, or stored. The solubility and mobility of perchlorate lends itself to ground water contamination, and some of these sources are used for drinking water. Perchlorate in drinking water has been determined at sub-mug l(-1) levels by extraction of the ion-pair formed between the perchlorate ion and a cationic surfactant with electrospray-mass spectrometry detection. Confidence in the selective quantification of the perchlorate ion is increased through both the use of the mass based detection as well as the selectivity of the ion pair. This study investigates several extraction solvents and experimental work-up procedures in order to achieve high sample throughput. The method detection limit for perchlorate based on 3.14sigma(n-1) of seven replicate injections was 300 ng l(-1) (parts-per-trillion) for methylene chloride extraction and 270 ng l(-1) for methyl isobutyl ketone extraction. Extraction with methylene chloride produces linear calibration curves, enabling standard addition to be used to quantify perchlorate in drinking water. Perchlorate determination of a contaminated water compared favorably with results determined by ion chromatography.
More Related Videos
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Precipitation and Co-precipitation
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Extraction: Advanced Methods
Precipitation of Ions
The equation that describes the equilibrium between solid calcium carbonate and its solvated ions is:

