Determination of Inorganic Arsenic in a Wide Range of Food Matrices using Hydride Generation - Atomic Absorption Spectrometry.
Published on: September 1, 2017
Multivariate optimisation of hydride generation procedures for single element determinations of As, Cd, Sb and Se in
J Moreda-Piñeiro1, C Moscoso-Pérez, P López-Mahía
1Department of Analytical Chemistry, Faculty of Sciences, University of A Coruña, Campus da Zapateira s/n, E-15071, A Coruña, Spain.
Abstract:
Continuous flow hydride generation procedures for As(III), total inorganic As, Cd, total inorganic Sb, Se(IV) and total inorganic Se from sea and hot-spring water samples were optimised by experimental designs. Ir-coated graphite tubes were used as preconcentration and atomisation medium of the hydrides generated. Several factors affecting the hydride generation efficiency were studied. Results obtained from Plackett-Burman designs suggest that sodium borohydride flow rate and reduction coil length, are significant factors for total inorganic arsenic hydride generation. For cadmium hydride generation the significant factors are hydrochloric acid concentration, hydrochloric acid and sodium borohydride flow rates and reduction coil length. For total inorganic antimony hydride generation the factors affecting the hydride generation procedure are hydrochloric acid and potassium iodide concentrations and reduction coil length; finally, pre-reduction coil length and oven temperature for the pre-reduction step are statistically significant factors for total inorganic selenium hydride generation. In addition, the factors studied for the arsenic and selenium hydride generation from As(III) and Se(IV) are not significant. From these studies, the significant variables were optimised by central composite designs. Validation carried out analysis on three reference materials: SLRS-4 (Riverie water), CASS-3 (seawater) and NIST-1643d.
More Related Videos
Related Concept Videos
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Atomic Absorption Spectroscopy: Atomization Methods
Atomic Emission Spectroscopy: Overview
Atomic Emission Spectroscopy: Instrumentation
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Atomic Emission Spectroscopy: Lab