Voltammetry: Stripping Methods01:13

Voltammetry: Stripping Methods

Anodic Stripping Voltammetry (ASV), Cathodic Stripping Voltammetry (CSV), and Adsorptive Stripping Voltammetry (AdSV) are electrochemical techniques used to determine trace amounts of analytes in solution. These methods involve applying a potential to an electrode and measuring the resulting current.
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Gas Chromatography: Sample Injection Systems01:08

Gas Chromatography: Sample Injection Systems

In gas chromatography, the sample is introduced as a vapor plug into the carrier gas stream for high efficiency and resolution. A microsyringe injects the sample solution into a heated sample port, vaporizing it and mixing it with the carrier gas. This process is important to ensure the sample is properly prepared for analysis. Thermally sensitive samples can be injected directly into the column and volatilized by slowly increasing the column temperature.
Two primary injection methods are used...
Voltammetric Techniques: Linear-Scan (E vs Time)01:12

Voltammetric Techniques: Linear-Scan (E vs Time)

Polarography is a classical voltammetric technique used to analyze electrochemical reactions. This method applies a linear potential sweep to a dropping mercury electrode (DME), and the resulting current is measured. A dropping mercury electrode is commonly used as the working electrode in polarography. It consists of a capillary tube filled with mercury, where the tiny droplet forms at the tip. This droplet continuously drops from the capillary, creating a new electrode surface for each...
Capillary Electrophoresis: Instrumentation01:20

Capillary Electrophoresis: Instrumentation

Capillary electrophoresis instrumentation typically consists of several key components. A high-voltage power supply generates the electric field necessary for the separation by connecting to an anode (the positively charged electrode) and a cathode (the negatively charged electrode) located in buffer reservoirs at each end of the capillary tube. The system includes a sample vial, a fused silica capillary tube coated with polyimide for mechanical strength through which the sample components...
Voltammetric Techniques: Cyclic Voltammetry01:10

Voltammetric Techniques: Cyclic Voltammetry

Cyclic voltammetry (CV) is an electrochemical technique used to investigate the redox properties of a chemical species. It involves measuring the current response of an electrochemical cell as a function of the applied potential. The setup for cyclic voltammetry typically consists of a working electrode, a reference electrode, and a counter electrode—all immersed in an electrolyte solution. The working electrode is where the redox reaction of interest occurs, while the reference electrode...
Gas Chromatography: Types of Detectors-II01:19

Gas Chromatography: Types of Detectors-II

In gas chromatography, different detectors are employed to meet specific analytical needs. These detectors are often categorized based on their detection mechanisms and the types of compounds they are best suited to analyze. Thermal Conductivity Detectors (TCD), Flame Ionization Detectors (FID), and Electron Capture Detectors (ECD) represent common categories, each with unique operating principles and applications. However, beyond these, several other detectors are designed for more specialized...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Modeling potentiometric sensitivity of conducting polymers.

Analytical chemistry·2011
Same author

Titration of strong and weak acids by sequential injection analysis technique.

Talanta·2008
Same author

Interferences in a polypyrrole-based amperometric ammonia sensor.

Talanta·2008
Same author

Spectrophotometric determination of iron(III) and total iron by sequential injection analysis technique.

Talanta·2008
Same author

Novel flow injection methods for drug-receptor interaction studies, based on probing cell metabolism.

The Analyst·2000
Same author

Bioligand interaction assay by flow injection absorptiometry.

Analytical chemistry·1998

Related Experiment Video

Updated: Jun 28, 2026

High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
10:17

High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry

Published on: April 23, 2019

The sequential injection system with adsorptive stripping voltammetric detection.

W W Kubiak1, R M Latonen, A Ivaska

  • 1Faculty of Materials Science and Ceramic, University of Mining and Metallurgy, al. Mickiewicza 30, PL 30-059 Krakow, Poland.

Talanta
|October 31, 2008
PubMed
Summary

Developed sequential injection systems enable sensitive adsorptive stripping voltammetry for riboflavin and metal ion determination. These methods offer high reproducibility and low detection limits for applications in food analysis and environmental monitoring.

More Related Videos

Analysis of Volatile and Oxidation Sensitive Compounds Using a Cold Inlet System and Electron Impact Mass Spectrometry
05:48

Analysis of Volatile and Oxidation Sensitive Compounds Using a Cold Inlet System and Electron Impact Mass Spectrometry

Published on: September 5, 2014

Automated 90Sr Separation and Preconcentration in a Lab-on-Valve System at Ppq Level
08:53

Automated 90Sr Separation and Preconcentration in a Lab-on-Valve System at Ppq Level

Published on: June 6, 2018

Related Experiment Videos

Last Updated: Jun 28, 2026

High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
10:17

High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry

Published on: April 23, 2019

Analysis of Volatile and Oxidation Sensitive Compounds Using a Cold Inlet System and Electron Impact Mass Spectrometry
05:48

Analysis of Volatile and Oxidation Sensitive Compounds Using a Cold Inlet System and Electron Impact Mass Spectrometry

Published on: September 5, 2014

Automated 90Sr Separation and Preconcentration in a Lab-on-Valve System at Ppq Level
08:53

Automated 90Sr Separation and Preconcentration in a Lab-on-Valve System at Ppq Level

Published on: June 6, 2018

Area of Science:

  • Analytical Chemistry
  • Electrochemistry

Background:

  • Adsorptive stripping voltammetry (AdSV) is a sensitive electroanalytical technique.
  • Sequential injection analysis (SIA) offers automation and reduced sample consumption.

Purpose of the Study:

  • To develop and validate two sequential injection systems for adsorptive stripping voltammetric measurements.
  • To determine riboflavin and various metal ions with high sensitivity and reproducibility.

Main Methods:

  • Development of two sequential injection systems for AdSV.
  • System 1: Direct aspiration for mercury-adsorbing substances (e.g., riboflavin).
  • System 2: Sample and ligand aspiration for complexing metal ions prior to deposition.

Main Results:

  • System 1 achieved 3% reproducibility and a 0.07 µM detection limit for riboflavin.
  • System 2 achieved <0.1 ppm detection limits for Cd, Pb, and Cu using oxine.
  • Lower detection limits (<0.01 ppm) were achieved for Ni and Co using dimethylglyoxime and nioxime.
  • Simultaneous determination of multiple metal ions (e.g., Cu, Pb, Cd, Co) was demonstrated.

Conclusions:

  • The developed SIA-AdSV systems provide efficient and sensitive analytical methods.
  • These systems are applicable for determining riboflavin in vitamin pills and studying its photodegradation.
  • The methods are suitable for trace metal ion analysis in environmental samples and complex matrices.