Related Experiment Video
Updated: Jun 28, 2026

Chemical Isolation, Quantification, and Separation of Skin Lipids from Reptiles
Published on: February 7, 2019
Chromium speciation using activated alumina microcolumns and sequential injection analysis-flame atomic absorption
M J Marqués1, A Morales-Rubio, A Salvador
1Department of Analytical Chemistry, University of Valencia, 50 Dr Moliner Street, 46100 Burjassot (Valencia), Spain.
Abstract:
A new procedure has been developed for chromium speciation in water by sequential injection analysis and flame atomic absorption spectrometry. The method involves the online retention of Cr(VI) anionic species and Cr(III) cationic species on alumina microcolumns, prepared by packing activated alumina in polytetrafluoroethylene tubes, followed by selective elution of Cr(VI) with 2 mol l(-1) NH(4)OH and of Cr(III) with 0.2 mol l(-1) HNO(3). Studies were carried out on the effect of retention and elution conditions for both Cr species. The limit of detection values, established as the concentration corresponding to three times the standard deviation of blank measurements divided by the slope of the calibration line, achieved were 42 mug l(-1) for Cr(VI) and 81 mug l(-1) for Cr(III). The relative standard deviation of three independent determination of natural spiked samples were lower than 10% for concentration levels between 0.5 and 2 mg l(-1) of Cr. The developed procedure was applied to the analysis of two effluent sewage waters, and results obtained compared well with those obtained by a batch procedure. Recovery studies on natural spiked samples provided results between 93 and 103% for Cr(VI) and from 100 to 106% for Cr(III) for samples spiked with single species. For samples spiked with both Cr(VI) and Cr(III), the average recoveries varied from 86 to 101% for Cr(VI) and from 91 to 117% for Cr(III).
More Related Videos
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
05:35Quantification of Metal Leaching in Immobilized Metal Affinity Chromatography
Published on: January 17, 2020
Related Concept Videos
Ion-Exchange Chromatography
Principles Of Column Chromatography
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Atomic Absorption Spectroscopy: Atomization Methods
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Types of Detectors-II