Rapid aqueous sample extraction of volatile organic compounds: effect of sample matrix and analyte properties
M J Meyer1, M F Gress, A J Borgerding
1Department of Chemistry, University of North Dakota, PO Box 9024, Grand Forks, ND 58202-9024, USA.
Abstract:
Studies have been done using a rapid aqueous sample extraction (RASE) system to characterize the effects of chemical properties on the time required for removal of volatile organic compounds (VOCs) to the gas phase. These analyses include determinations of the effects that different analytes, and modifications to the matrix, have on extraction time. Experiments were performed to determine the distinct contributions of analyte removal from water and gas-phase transport to the duration of the extracted pulse of analytes. These measured durations were correlated with known values of Henry's law constants (K(H)), boiling points, relative volatilities from modified matrixes, and aqueous diffusion coefficients for cyclohexane, toluene, o-xylene, isopropylbenzene (IPB), and o-dichlorobenzene. Transport time, which was the most significant contributor to the overall duration, correlated well with analyte boiling point. Analyte removal from water correlated better with a modified relative volatility measurement than either K(H) or D(L). IPB extraction was studied in a number of modified matrixes. A 0.1% methanol in water matrix resulted in a 35% decrease in the extraction time of IPB relative to pure water. Extraction time decreased by 22% with the addition of 0.1% NaCl to the aqueous matrix. The addition of 0.01% sodium dodecyl sulfate to the matrix resulted in a 13% increase in the extraction time of IPB relative to water. The RASE system was directly interfaced to a cryofocussing high-speed gas chromatography system to analyze VOCs in wastewater at the low mug l(-1) level.
More Related Videos
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
05:20Determination of 45 Pesticides in Avocado Varieties by the QuEChERS Method and Gas Chromatography-Tandem Mass Spectrometry
Published on: December 8, 2023
Related Concept Videos
Volatilization
Sample Preparation for Analysis: Overview
Bulk or large solid samples are typically reduced in size using grinding, crushing, or milling techniques to increase the...
Extraction: Advanced Methods
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Sampling Methods: Sample Types
Solid samples include a variety of substances, such as sediments from water bodies, soil, metals, and biological tissues. Two standard methods for extracting sediments from water bodies are grab sampling and piston coring. Grab sampling involves using a device to collect a discrete sediment sample from the bottom of a water body with minimal disturbance. Grab samples do not always represent the entire area due to...
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...