Fast flow-injection fluorimetric determination of amiloride by using a solid sensing zone.
A Domínguez-Vidal1, P Ortega-Barrales, A Molina-Díaz
1Faculty of Experimental Sciences, Department of Physical and Analytical Chemistry, University of Jaén, 23071 Jaén, Spain.
A new solid-phase spectrofluorimetric method determines the diuretic amiloride in serum and pharmaceuticals. This rapid, simple flow-injection analysis system offers sensitive and reliable detection without sample pretreatment.
Area of Science:
- Analytical Chemistry
- Spectrofluorimetry
- Flow-Injection Analysis
Background:
- Accurate determination of the diuretic amiloride is crucial for therapeutic monitoring and pharmaceutical quality control.
- Existing analytical methods may require complex sample preparation or derivatization steps.
- Development of rapid, sensitive, and direct detection methods is needed for physiological fluids and pharmaceutical samples.
Purpose of the Study:
- To develop and validate a rapid, simple, flow-through solid-phase spectrofluorimetric system for amiloride determination.
- To enable direct measurement of amiloride's intrinsic fluorescence in serum and pharmaceutical preparations.
- To establish a sensitive and reliable analytical method with minimal sample pretreatment.
Main Methods:
- A monochannel flow-injection analysis system coupled with a spectrofluorimetric detector was employed.
- Amiloride was retained on a cationic exchanger gel (Sephadex SP-C25) in the detection cell.
- Direct measurement of intrinsic fluorescence at excitation/emission wavelengths of 291/419 nm, using peak height as the analytical signal.
Main Results:
- The method achieved concentration ranges of 10-600 µg/L and 4-250 µg/L with sampling rates of 24 h⁻¹ and 30 h⁻¹, respectively.
- Detection limits were as low as 0.92 µg/L and 0.33 µg/L for different sample volumes.
- Excellent precision was demonstrated with relative standard deviations better than 0.65% for independent determinations.
Conclusions:
- The developed solid-phase spectrofluorimetric system provides a rapid, simple, and sensitive method for amiloride quantification.
- The method is effective for analyzing amiloride in spiked biological fluids (serum) and pharmaceutical preparations without prior sample treatment.
- This approach offers a valuable tool for routine analysis in clinical and pharmaceutical settings.
More Related Videos
09:58Computer Numerical Control Micromilling of a Microfluidic Acrylic Device with a Staggered Restriction for Magnetic Nanoparticle-Based Immunoassays
Published on: June 23, 2022
10:52Radiolabeling and Quantification of Cellular Levels of Phosphoinositides by High Performance Liquid Chromatography-coupled Flow Scintillation
Published on: January 6, 2016
Related Concept Videos
Amperometry: Overview
High-Performance Liquid Chromatography: Types of Detectors