A study of robustness with multivariate calibration. Application to the polarographic determination of benzaldehyde

M B Sanz1, L A Sarabia, A Herrero

  • 1Department of Chemistry, Faculty of Sciences, University of Burgos, Plaza Misael Bañuelos s/n, 09001 Burgos, Spain.

Talanta
|October 31, 2008
PubMed

Related Concept Videos

IR and UV–Vis Spectroscopy of Aldehydes and Ketones01:29

IR and UV–Vis Spectroscopy of Aldehydes and Ketones

Infrared spectroscopy, also known as vibrational spectroscopy, is mainly used to determine the types of bonds and functional groups in molecules. In aldehydes and ketones, the carbonyl (C=O) bond shows an absorption around 1710 cm-1. The C=O bond vibration of an aldehyde occurs at lower frequencies than that of a ketone. In addition to the C=O absorption in an aldehyde, the aldehydic C–H bond also gives two peaks in the 2700–2800 cm-1 range. This absorption, coupled with the C=O stretching, is...
Voltammetry: Factors Affecting Measurements01:21

Voltammetry: Factors Affecting Measurements

A current produced due to the redox reactions of the analyte at the working and auxiliary electrodes is called a faradaic current. The reaction can be divided into two types. The current generated due to the reduction of the analyte is called cathodic current, and it carries a positive charge. In contrast, the current produced by analyte oxidation is known as an anodic current, and it has a negative charge. The applied potential at the working electrode determines the faradaic current flow, and...
Voltammetric Techniques: Linear-Scan (E vs Time)01:12

Voltammetric Techniques: Linear-Scan (E vs Time)

Polarography is a classical voltammetric technique used to analyze electrochemical reactions. This method applies a linear potential sweep to a dropping mercury electrode (DME), and the resulting current is measured. A dropping mercury electrode is commonly used as the working electrode in polarography. It consists of a capillary tube filled with mercury, where the tiny droplet forms at the tip. This droplet continuously drops from the capillary, creating a new electrode surface for each...
NMR Spectroscopy of Benzene Derivatives01:37

NMR Spectroscopy of Benzene Derivatives

Simple unsubstituted benzene has six aromatic protons, all chemically equivalent. Therefore, benzene exhibits only a singlet peak at δ 7.3 ppm in the 1H NMR spectrum. The observed shift is far downfield because the aromatic ring current strongly deshields the protons. Any substitution on the benzene ring makes the aromatic protons nonequivalent, and the protons split each other. The peak is, therefore, no longer a singlet and the splitting pattern and their associated coupling constants depend...
Calibration Curves: Linear Least Squares01:20

Calibration Curves: Linear Least Squares

A calibration curve is a plot of the instrument's response against a series of known concentrations of a substance. This curve is used to set the instrument response levels, using the substance and its concentrations as standards. Alternatively, or additionally, an equation is fitted to the calibration curve plot and subsequently used to calculate the unknown concentrations of other samples reliably.
For data that follow a straight line, the standard method for fitting is the linear...
Measuring Reaction Rates03:09

Measuring Reaction Rates

Polarimetry finds application in chemical kinetics to measure the concentration and reaction kinetics of optically active substances during a chemical reaction. Optically active substances have the capability of rotating the plane of polarization of linearly polarized light passing through them—a feature called optical rotation. Optical activity is attributed to the molecular structure of substances. Normal monochromatic light is unpolarized and possesses oscillations of the electrical field in...