Simple flow injection system for colorimetric determination of iodate in iodized salt

N Choengchan1, K Uraisin, K Choden

  • 1Department of Chemistry, Faculty of Science, Mahidol University, Rama 6 Road, Bangkok 10400, Thailand.

Talanta
|October 31, 2008
PubMed

Related Concept Videos

Redox Titration: Iodimetry and Iodometry01:23

Redox Titration: Iodimetry and Iodometry

Iodometry and iodimetry are analytical methods used to determine the concentration of oxidizing or reducing agents using iodine. In iodometric titrations, the oxidizing analyte solution is usually acidified and treated with an excess of iodide ions, which generates an equivalent amount of iodine in equilibrium with triiodide. The released iodine is subsequently titrated directly against a standardized reducing agent. As the dilute iodine color becomes pale yellow, a few drops of freshly...
Redox Titration: Overview01:21

Redox Titration: Overview

Redox titration is a chemical analysis technique used to determine the concentration of an unknown substance by measuring the electron transfer in a redox (reduction-oxidation) reaction. The process involves gradually adding a titrant with a known concentration of an oxidizing or reducing agent, to the analyte, the solution with an unknown concentration, until reaching the endpoint, which indicates the completion of the reaction between the two substances. Ensuring the analyte is in a single...
Flame Photometry: Lab01:16

Flame Photometry: Lab

In a flame photometer, when a solution like potassium chloride is aspirated into the flame, the solvent evaporates, leaving behind dehydrated salt. This salt dissociates into free gaseous atoms in their ground state. Some of these atoms absorb energy from the flame, leading to their excitation. The excited atoms return to the ground state, emitting photons at characteristic wavelengths. Because only electronic transitions are involved, the resulting emission lines are very narrow. The intensity...
Precipitation Titration: Endpoint Detection Methods01:19

Precipitation Titration: Endpoint Detection Methods

In argentometric precipitation titrations, endpoints can be detected visually by the Mohr, Volhard, and Fajans methods. In the Mohr method, adding a soluble chromate indicator gives an initial yellow color to the analyte solution. As the titrant is added, the first excess of silver ions forms a red silver chromate precipitate, marking the endpoint. The solution pH should be maintained at about 8 by adding solid CaCO3.
In the Volhard method, a standard excess of AgNO3 is first added to the...
Precipitation Titration Curve: Analysis01:21

Precipitation Titration Curve: Analysis

The precipitation titration curve demonstrates the change in concentration of one reactant with the volume of titrant added. During the titration of chloride ions with silver nitrate, the precipitation titration curve is divided into three regions: before, at, and after the equivalence point. Before the equivalence point, low redissolution of the sparingly soluble silver chloride precipitate gives a low silver ion concentration. However, in the second region, representing the equivalence point,...
Precipitation of Ions03:11

Precipitation of Ions

Predicting Precipitation
The equation that describes the equilibrium between solid calcium carbonate and its solvated ions is: