Artificial neural networks for simultaneous spectrophotometric differential kinetic determination of Co(II) and V(IV)

A Safavi1, H Abdollahi, M R Hormozi Nezhad

  • 1Department of Chemistry, College of Sciences, Shiraz University, Shiraz 71454, Iran.

Talanta
|October 31, 2008
PubMed

Related Concept Videos

Spectrophotometry: Introduction01:16

Spectrophotometry: Introduction

Spectrophotometry is the quantitative measurement of the absorption, reflection, diffraction, or transmission of electromagnetic radiation through a material as a function of the intensity and wavelength of the radiation. A spectrophotometer is a device used to measure the change in the radiation intensity caused by its interaction with the material.
The essential components of a spectrophotometer include a source of electromagnetic radiation, a slot for placing a material to be analyzed, and a...
Estimation of k and VD of Aminoglycosides01:20

Estimation of k and VD of Aminoglycosides

Aminoglycosides are a class of antibiotics used to treat various bacterial infections. Clinicians must determine the elimination rate constant (k) and volume of distribution (VD) to optimize therapeutic efficacy and minimize toxicity. The k value represents the rate at which the drug is removed from the body, and the VD reflects the degree to which the drug distributes into body tissues. Accurately estimating these parameters allows healthcare professionals to tailor drug dosing to individual...
UV–Vis Spectroscopy: Woodward–Fieser Rules01:29

UV–Vis Spectroscopy: Woodward–Fieser Rules

UV–Visible absorption spectra of conjugated dienes arise from the lowest energy π → π* transitions. The light-absorbing part of the molecule is called the chromophore, and the substituents directly attached to the chromophore are called auxochromes. A strong correlation exists between the absorption maxima, λmax, and the structure of a conjugated π system. The Woodward–Fieser rules predict the value of λmax for a given structure by adding the contributions...
UV–Vis Spectrometers01:14

UV–Vis Spectrometers

The absorbance of UV and visible (UV–visible) radiations is measured using a UV–visible spectrophotometer. Deuterium lamps, which emit UV radiation, and tungsten lamps, which produce radiation in the visible region, are used as light sources in UV–visible spectrophotometers. A monochromator or prism is used for diffraction grating, i.e., to split the incoming radiation into different wavelengths. A system of slits is used to focus the desired wavelength on the sample cell. Samples for...
UV–Vis Spectroscopy of Conjugated Systems01:32

UV–Vis Spectroscopy of Conjugated Systems

Organic compounds with conjugated double bonds show strong absorption features in the UV–visible region of the electromagnetic spectrum attributed to π → π* electronic excitations. Generally, a UV–vis absorption spectrum is recorded as a plot of absorbance vs wavelength. The wavelength of maximum absorbance, which manifests as a peak in the absorption spectrum, is denoted as λmax.
One of the factors influencing λmax is the extent of conjugation in the...
Complexometric EDTA Titration Curves01:20

Complexometric EDTA Titration Curves

EDTA titration curves determine the free metal ion concentration. The titration curve represents the change in concentration of free metal ions (p function) as a function of the volume of EDTA added. This curve consists of three regions: before, at, and after equivalence points. Excess free metal ions are present before the equivalence point. Equal concentrations of metal ions and EDTA are present at the equivalence point. After the equivalence point, excess EDTA exists. This means slight...