Related Experiment Video
Updated: Jun 28, 2026

Optimized Griess Reaction for UV-Vis and Naked-eye Determination of Anti-malarial Primaquine
Published on: October 11, 2019
Determination of paraquat in human blood plasma using reversed-phase ion-pair high-performance liquid chromatography
M R Brunetto1, A R Morales, M Gallignani
1Faculty of Sciences, IVAIQUIM (Venezuelan Andean Institute of Chemistry), University of Los Andes, Ipostel La Hechicera, Mérida 5101-A, Venezuela. brunetto@via.ve
Abstract:
This report describes the determination of paraquat (PQ) in human blood plasma samples by a direct-injection reversed-phase ion-pair chromatographic method. Blood plasma filtrate was injected directly into the LiChrospher(R) RP-18 alkyl-diol silica (ADS) precolumn integrated in a column switching system using a mixture of 3% 2-propanol and 10 mM sodium octane sulfonate (SOS) in a 0.05 M phosphate buffer (pH 2.8). After washing with this phase, the ADS precolumn was back-flushed with the analytical mobile phase consisting of 40% of methanol and 10 mM SOS in a 0.05 M phosphate buffer (pH 2.8) at a flow rate of 1.0 ml min(-1), in order to carry the analyte to a conventional reversed-phase analytical column, where the separation of PQ was achieved and finally detected by UV at 258 nm. The recoveries of PQ from human blood plasma samples ranged between 95.0 and 99.5% at nine different concentrations (from 0.05 to 3.00 microg of PQ ml(-1)) with coefficients of variation <2.5% (n=3). The precision expressed as relative standard deviation was below 3.5% for between-day and below 4.3% for within-day measurements (n=5). The detection limit (signal-to-noise ratio, S/N>3) was 0.005 microg ml(-1) with an injection volume of 200 microl. The proposed method is promising for the identification and quantification of PQ at low concentration levels and is suitable for its analysis in human blood plasma samples from intentional or accidental poisonings cases with a sample throughput of 5 samples per hour.
More Related Videos
14:39Semi-Targeted Ultra-High-Performance Chromatography Coupled to Mass Spectrometry Analysis of Phenolic Metabolites in Plasma of Elderly Adults
Published on: April 22, 2022
05:20Determination of 45 Pesticides in Avocado Varieties by the QuEChERS Method and Gas Chromatography-Tandem Mass Spectrometry
Published on: December 8, 2023
Related Concept Videos
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Types of Detectors
High-Performance Liquid Chromatography: Instrumentation
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview