Flow-through bulk optode for the fluorimetric determination of perchlorate
J A Ortuño1, M I Albero, M S García
1Department of Analytical Chemistry, Faculty of Chemistry, University of Murcia, 30071 Murcia, Spain.
A novel fluorescence bulk optode enables rapid flow-injection determination of perchlorate. This sensor offers reliable analysis of perchlorate in various water samples, showcasing its practical application.
Area of Science:
- Analytical Chemistry
- Environmental Science
Background:
- Perchlorate is an environmental contaminant requiring sensitive detection methods.
- Existing methods for perchlorate determination can be time-consuming or require complex instrumentation.
Purpose of the Study:
- To develop and characterize a flow-through fluorescence bulk optode for perchlorate determination.
- To evaluate the optode's performance in the flow-injection analysis of perchlorate in environmental water samples.
Main Methods:
- A bulk optode was constructed using a plasticized poly(vinyl) chloride membrane containing fluorescein octadecyl ester and methyl tridodecyl ammonium chloride.
- The optode was integrated into a flow-injection analysis (FI) system for perchlorate detection at pH 4.5.
- Sensor regeneration was achieved using a TRIS buffer at pH 10.4.
Main Results:
- The developed optode demonstrated a rapid response time for perchlorate.
- The analytical characteristics, including dynamic measurement range, reproducibility, and selectivity, were evaluated.
- The FI method successfully determined perchlorate concentrations in diverse water sources.
Conclusions:
- The flow-through fluorescence bulk optode is a viable sensor for the selective and reproducible determination of perchlorate.
- The proposed FI method offers a practical approach for on-site perchlorate monitoring in environmental waters.
More Related Videos
06:59A Fluorescence-Based Assay of Membrane Potential for High-Throughput Functional Study of Two Endogenous Ion Channels in Two Epithelial Cell Lines
Published on: June 22, 2022
05:17Fast and Specific Assessment of the Halogenating Peroxidase Activity in Leukocyte-enriched Blood Samples
Published on: July 28, 2016
Related Concept Videos
Flame Photometry: Lab
Amperometry: Overview
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Photoluminescence: Applications