Determination of cadmium in biological samples solubilized with tetramethylammonium hydroxide by electrothermal
José Bento Borba da Silva1, Daniel Lázaro Gallindo Borges, Márcia Andréia Mesquita Silva da Veiga
1Departamento de Química, Universidade Federal de Minas Gerais, Belo Horizonte, MG, Brazil.
Abstract:
The feasibility of Ru as a permanent modifier for the determination of Cd in biological samples treated with tetramethylammonium hydroxide (TMAH) by ET AAS was investigated. The tube treatment with Ru was carried out only once and lasted for about 300 atomization cycles. The pyrolysis and atomization temperatures, 750 degrees C and 1300 degrees C, respectively, were chosen from the temperature curves. The sample dissolution procedure was very simple: a sample aliquot was mixed with a small volume of a 25% m/v TMAH solution, the volume was made up to 50 ml and the mixture was kept at 60 degrees C for 1 h. Six certified biological reference materials were analyzed and the obtained Cd concentrations are within the 95% confidence interval of the certified values, proving the accuracy of the proposed procedure for a variety of biological samples. The calibration curve, with correlation coefficient higher than 0.99, was established for a working range up to 10 microg l(-1). The precision was good as demonstrated by relative standard deviations below 3%, except for one sample. The limit of detection (3sigma) was 0.05 microg l(-1) and the characteristic mass was 1.30 pg, obtained in the presence of the Ru modifier.
More Related Videos
07:12Synthesis and Evaluation of a Ruthenium-based Mitochondrial Calcium Uptake Inhibitor
Published on: October 26, 2017
08:46Dose Uptake of Platinum- and Ruthenium-based Compound Exposure in Zebrafish by Inductively Coupled Plasma Mass Spectrometry with Broader Applications
Published on: April 21, 2022
Related Concept Videos
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...