Development of methodologies to determine aluminum, cadmium, chromium and lead in drinking water by ET AAS using

Luciano de Almeida Pereira1, Ilmair Gonçalves de Amorim, José Bento Borba da Silva

  • 1Departamento de Quimica, Universidade Federal de Minas Gerais, Avenida Antônio Carlos 6627, 31270-901 Belo Horizonte, MG, Brazil.

Talanta
|October 31, 2008
PubMed

Related Concept Videos

Effects of EDTA on End-Point Detection Methods01:18

Effects of EDTA on End-Point Detection Methods

Different methods, such as visual observance of metal-ion indicators, spectroscopic techniques, and potentiometric methods, can determine the endpoint of an EDTA titration.
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
Atomic Absorption Spectroscopy: Lab01:21

Atomic Absorption Spectroscopy: Lab

For AAS measurements, samples must be introduced as clear solutions, often requiring extensive preliminary treatment to dissolve materials like soils, animal tissues, and minerals. Common methods for sample preparation include treatment with hot mineral acids, wet ashing, combustion in closed containers, high-temperature ashing, or fusion with reagents.
 Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
EDTA: Indirect and Alkalimetric Titration01:23

EDTA: Indirect and Alkalimetric Titration

Unlike direct titration, back-titration, and displacement titration, indirect titration is an EDTA titration method for quantifying anions. In the indirect titration method, anions are precipitated as their insoluble salts with excess metal ions. The filtrate containing the excess metal ions is directly titrated with standard EDTA until the endpoint is achieved. Another approach involves extracting the metal ion and back-titrating with standard EDTA to obtain the endpoint. In this way, the...
Atomic Absorption Spectroscopy: Overview01:27

Atomic Absorption Spectroscopy: Overview

Atomic absorption spectroscopy (AAS) is a technique used to analyze elements by measuring electromagnetic radiation (EMR) absorbed by atoms, which causes them to transition to a higher-energy orbit. The most crucial step in AAS is atomization, where the analyte is converted into gas-phase atoms, typically through a flame or furnace. Some of these atoms become thermally excited in the flame, while most remain in the ground state.
When irradiated by EMR of a particular wavelength, these...
Atomic Absorption Spectroscopy: Radiation and Light Sources01:13

Atomic Absorption Spectroscopy: Radiation and Light Sources

Atomic absorption spectroscopy (AAS) relies on the Beer-Lambert law, which requires that the radiation source emits a narrow range of wavelengths to match the absorption characteristics of the analyte atom. The primary criteria for choosing an appropriate radiation source in AAS is to provide a precise and intense emission at specific wavelengths that will allow accurate detection of the analyte.
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...
EDTA: Direct, Back-, and Displacement Titration01:30

EDTA: Direct, Back-, and Displacement Titration

The EDTA titration types for metal ion analysis include direct titration, back-titration, and replacement titration.
Direct titration involves buffering the metal ion solution to the desired pH and directly titrating with standard EDTA until the endpoint. The optimum pH ensures a large conditional formation constant of metal−EDTA and visibility of the free indicator color in the solution. In addition, auxiliary complexing reagents are used to prevent the precipitation of metal hydroxides and...