Determination of iodide by detection of iodine using gas-diffusion flow injection and chemiluminescence
N Ratanawimarnwong1, N Amornthammarong, N Choengchan
1Department of Chemistry, Faculty of Science, Mahidol University, Rama 6 Rd, Bangkok 10400, Thailand.
Abstract:
This work describes development of a flow injection (FI) system for determination of iodide, based on the chemiluminescence (CL) reaction between iodine and luminol. Iodide in the sample zone is oxidized to iodine. Employment of a gas-diffusion (GD) unit allows for selective detection of the generated CL (425nm). Preliminary results showed for concentrations of less than 2mgL(-1), that signals were irreproducible and that the calibration was not linear. In order to solve these problems, a method of 'membrane conditioning' was investigated, in which iodide stream was continuously merged with oxidant to generate I(2) that conditioned the GD membrane and tubing. This minimized surface interaction between the active surface and the I(2) generated from the samples, thus improving both precision and sensitivity. By employing membrane conditioning, it has been possible to reliably detect concentrations down to 0.1mgL(-1). At the optimized condition, an excellent linear calibration (r(2) = 0.999) was obtained from 0.1 to 1.0mgL(-1). The method was successfully applied to determine iodide in some pharmaceutical products such as potassium iodide tablets and a liquid patent medicine. However, for vitamin tablets, ascorbic acid was found to interfere seriously by causing a negative signal.
More Related Videos
08:23Chemiluminescence-based Assays for Detection of Nitric Oxide and its Derivatives from Autoxidation and Nitrosated Compounds
Published on: February 16, 2022
08:25Measuring Nitrite and Nitrate, Metabolites in the Nitric Oxide Pathway, in Biological Materials using the Chemiluminescence Method
Published on: December 25, 2016
Related Concept Videos
Redox Titration: Iodimetry and Iodometry
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Photoluminescence: Applications
Ion-Exchange Chromatography
Flame Photometry: Lab