Application of diffusive gradient in thin films technique (DGT) to measurement of mercury in aquatic systems

H Docekalová1, P Divis

  • 1Faculty of Chemistry, Brno University of Technology, Purkynova 118, 61200 Brno, Czech Republic.

Talanta
|October 31, 2008
PubMed

Related Concept Videos

Voltammetric Techniques: Linear-Scan (E vs Time)01:12

Voltammetric Techniques: Linear-Scan (E vs Time)

Polarography is a classical voltammetric technique used to analyze electrochemical reactions. This method applies a linear potential sweep to a dropping mercury electrode (DME), and the resulting current is measured. A dropping mercury electrode is commonly used as the working electrode in polarography. It consists of a capillary tube filled with mercury, where the tiny droplet forms at the tip. This droplet continuously drops from the capillary, creating a new electrode surface for each...
Gravimetry: Overview01:05

Gravimetry: Overview

Gravimetric analysis is a quantitative method where the analyte is isolated and weighed directly or after conversion into a substance of known composition. Gravimetric analysis can be classified as precipitation, electrogravimetry, volatilization, and particulate gravimetry, based on the method used to isolate the analyte.
In precipitation gravimetry, the analyte is converted into a precipitate and weighed. For example, the silver content in a sample can be estimated by precipitating and...
Precipitation Gravimetry01:03

Precipitation Gravimetry

Precipitation gravimetry is based on converting an analyte into a sparingly soluble precipitate, which is separated by filtration and weighed. An ideal precipitate should be pure, insoluble, of known composition, and easily filtered from the reaction mixture.
In determining nickel by gravimetric analysis, a precipitant of ethanolic dimethylglyoxime is added to a hot nickel salt solution. This is quickly followed by the dropwise addition of dilute ammonia solution until precipitation occurs. A...
Diffusion on Chromatography Columns01:07

Diffusion on Chromatography Columns

In column chromatography, when an analyte is introduced as a narrow band at the top of the column, the solutes begin to separate and broaden, developing a Gaussian profile. This broadening occurs due to various factors, such as longitudinal diffusion.
Longitudinal diffusion occurs when the solute molecules in the mobile phase diffuse from the more concentrated center of the chromatographic band to the more dilute regions on either side, both towards and against the flow direction. This...
Microbial Growth Measurement: Indirect Methods01:27

Microbial Growth Measurement: Indirect Methods

Estimating microbial growth is essential for understanding population dynamics and environmental adaptations. Indirect methods provide valuable insights by measuring parameters such as turbidity, metabolic activity, and biomass, enabling efficient and reproducible assessments.During exponential growth, microbial cells scatter light proportionally to their biomass, a principle used in turbidity measurements. About one million cells per milliliter produce detectable scattering, which a...