Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Non-parametric linear regression of discrete Fourier transform convoluted chromatographic peak responses in non-ideal
Mohamed A Korany1, Ossama T Fahmy, Hoda Mahgoub
1Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, University of Alexandria, El-Mesala, Alexandria 21521, Egypt.
Abstract:
This manuscript discusses the application of chemometrics to the handling of HPLC response data using a model mixture containing ascorbic acid, paracetamol and guaiphenesin. Derivative treatment of chromatographic response data followed by convolution of the resulting derivative curves using 8-points sinx(i) polynomials (discrete Fourier functions) was found beneficial in eliminating different types of interferences. This was successfully applied to handle some of the most common chromatographic problems and non-ideal conditions, namely: very low analyte concentrations, overlapping chromatographic peaks and baseline drift. For example, a significant change in the correlation coefficient of guaiphenesin, in case of baseline drift, went from 0.9978 to 0.9998 on applying normal conventional peak area and first derivative under Fourier functions methods, respectively. It also compares the application of Theil's method, a non-parametric regression method, in handling the response data, with the least squares parametric regression method, which is considered the de facto standard method used for regression. Theil's method was found to be superior to the method of least squares as it assumes that errors could occur in both x- and y-directions and they might not be normally distributed. In addition, it could effectively circumvent any outlier data points.
More Related Videos
Related Concept Videos
Chromatographic Methods: Terminology
Chromatographic Resolution
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
High-Performance Liquid Chromatography: Types of Detectors
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...
Column Efficiency: Rate Theory
During elution, a solute molecule experiences numerous transitions between stationary and mobile phases, exhibiting irregular residence times in...