Related Experiment Video
Updated: Jun 28, 2026

Clean Sampling and Analysis of River and Estuarine Waters for Trace Metal Studies
Published on: July 1, 2016
Determination of lead in water samples by graphite furnace atomic absorption spectrometry after cloud point
Jianrong Chen1, Shanmei Xiao, Xiaohua Wu
1College of Chemistry and Life Science, Zhejiang Normal University, Jinhua, Zhejiang 321004, China.
Abstract:
Cloud point extraction (CPE) has been used for the pre-concentration of lead, after the formation of a complex with 2-(5-bromo-2-pyridylazo)-5-(diethylamino)-phenol (5-Br-PADAP), and later analysis by graphite furnace atomic absorption spectrometry (GFAAS) using octylphenoxypolyethoxyethanol (TritonX-114) as surfactant. The chemical variables affecting the separation phase were optimized. Separation of the two phases was accomplished by centrifugation for 15min at 4000rpm. Under the optimum conditions i.e., pH 8.0, cloud point temperature 40 degrees C, [5-Br-PADAP]=2.5x10(-5)moll(-1), [Triton X-114]=0.05%, added methanol volume=0.15ml, pre-concentration of only 10ml sample permitted an enhancement factor of 50-fold. The lower limit of detection (LOD) obtained under the optimal conditions was 0.08mugl(-1). The precision for 10 replicate determinations at 5mugl(-1) Pb was 2.8% relative standard deviation (R.S.D.). The calibration graph using the pre-concentration system for lead was linear with a correlation coefficient of 0.9984 at levels near the detection limits up to at least 30mugl(-1). The method was successfully applied to the determination of lead in water samples.
Related Concept Videos
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Sample Preparation for Analysis: Advanced Techniques
Acid digestion with strong acids is commonly used to dissolve inorganic materials that are insoluble (do not dissolve) in water. This method can be useful for...
Washing, Drying, and Ignition of Precipitates
Atomic Absorption Spectroscopy: Atomization Methods
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Precipitation Gravimetry
In determining nickel by gravimetric analysis, a precipitant of ethanolic dimethylglyoxime is added to a hot nickel salt solution. This is quickly followed by the dropwise addition of dilute ammonia solution until precipitation occurs. A...

