Sequential injection spectrophotometric determination of ritodrine hydrochloride using 4-aminoantipyrine
Jacobus F van Staden1, Negussie W Beyene, Raluca-Ioana Stefan
1Department of Chemistry, University of Pretoria, Pretoria 0002, South Africa.
Abstract:
A sequential injection spectrophotometric determination of ritodrine hydrochloride is described. The method is based on the condensation of aminoantipyrine with phenols in the presence of an alkaline oxidizing agent to yield a pink coloured product the absorbance of which is monitored at 503nm. Different sequential injection analysis (SIA) parameters including reagent concentrations have been optimised and used to obtain the analytical figures of merit. A linear concentration range of 3.1-123.5mumolL(-1) and a detection limit (as 3sigma-value) of 1.0mumolL(-1) were obtained. The precision was 2.4 and 2.3% relative standard deviation (R.S.D.) at 6.2 and 15.4mumolL(-1), respectively. This method is superior over previously reported ones in terms of linear range, short analysis time, high sample throughput, excellent reagent economy and minimum waste generation.