Preparation and application of monolithic columns with narrow immobilized pH gradients
Guijie Zhu1, Chun Yang, Lihua Zhang
1Department of Biotechnology, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, China; Graduate School of Chinese Academy of Sciences, Beijing 100039, China.
Abstract:
Monolith with immobilized pH gradient (M-IPG) is a novel separation matrix for amphoteric substances, such as peptides and proteins. To improve the properties of the newly designed column, efforts were made to optimize the preparation procedure, including the concentrations of the monomers, glycidyl methacrylate (GMA) and ethylene glycol dimethacrylate (EDMA), as well as the kinds of porogens, which led to a monolith with improved permeability, uniformity and continuity. In addition, different diamines, including ethylenediamine, 1,3-diaminopropane, 1,4-diaminobutane and 1,5-diaminopentane, were subjected to aminate the polymer, and the last two exhibited excellent reactivity with epoxy on the polymer surface, which could obviously make the immobilization of pH gradient facilitated. Under the optimal conditions, a simple method to prepare M-IPG column with narrow pH gradient was developed with commercial carrier ampholytes (CAs) solution. Such columns were applied into the analysis of proteins and peptides, and showed the improved resolution compared to the traditional one with a wide pH distribution.
Related Concept Videos
Types Of Column Chromatography
Gel Filtration Chromatography
When the...
Principles Of Column Chromatography
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...