Simultaneous determination of Al(III) and Fe(III) in post-hemodialysis fluids by spectrophotometry and multivariate
Paulo C Nascimento1, Cristiane L Jost, Marcos V Guterres
1Departamento de Química, Universidade Federal de Santa Maria, 97110-970 Santa Maria, RS, Brazil.
Abstract:
A multivariate calibration model (PLS) was developed for the simultaneous spectrophotometric determination of Al(III) and Fe(III) in post-hemodialysis fluids with pyrocathecol violet (PCV) as chromogenic reagent. The analytes build stable complexes with PCV in presence of hexamine buffered medium at pH 6.1. The complexes show overlapped absorption bands in the spectral range of 220-800nm so that absorptions of 580 wavelengths were necessary for the calibrations. Determinations of Al(III) and Fe(III) were done without masking agents. The best calibration model was obtained by using PLS-1 regression with three components after data mean centering. The spectrophotometric method applied to assay the analytes in real post-hemodialysis samples containing no desferrioxamine B presented good agreement with voltammetric measurements used as reference. Concentrations ranging from 0.20 to 0.60mgL(-1) for Al(III) and for Fe(III) were determined in real samples. The multivariate detection limits for Al(III) and Fe(III) were 0.044 and 0.052mgL(-1), respectively, and the calculated values of sensitivity were 6.33 for Al(III) and 3.44 for Fe(III). The proposed method showed to be straightforward and useful to follow the hemodialysis progress for patients under treatment. Interferents were also investigated.
More Related Videos
04:48Setup of Capillary Electrophoresis-Inductively Coupled Plasma Mass Spectrometry (CE-ICP-MS) for Quantification of Iron Redox Species (Fe(II), Fe(III))
Published on: May 4, 2020
09:45Laboratory Simulation of an Iron(II)-rich Precambrian Marine Upwelling System to Explore the Growth of Photosynthetic Bacteria
Published on: July 24, 2016
Related Concept Videos
EDTA: Indirect and Alkalimetric Titration
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Complexometric EDTA Titration Curves
EDTA: Direct, Back-, and Displacement Titration
Direct titration involves buffering the metal ion solution to the desired pH and directly titrating with standard EDTA until the endpoint. The optimum pH ensures a large conditional formation constant of metal−EDTA and visibility of the free indicator color in the solution. In addition, auxiliary complexing reagents are used to prevent the precipitation of metal hydroxides and...
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
