Related Experiment Video
Updated: Jun 28, 2026

Multi-Modal Home Sleep Monitoring in Older Adults
Published on: January 26, 2019
Reliability of a Holter-based methodology for evaluation of sleep apnoea syndrome
Ariel Szyszko1, Carlos Franceschini, Jorge Gonzalez-Zuelgaray
1Service of Arrhythmias and Electrophysiology, Instituto Argentino de Diagnostico y Tratamiento, Marcelo T. de Alvear 2346, 1122 Buenos Aires, Argentina. aes1974@gmail.com
Aims:
Sleep apnoea has significant medical implications. A reliable non-invasive method (as a regular Holter system with a specific software) would be valuable for the screening of this condition in ambulatory patients.
Methods And Results:
A total of 40 patients were divided into two groups: Group I, 20 patients with clinical suspicion of obstructive sleep apnoea (OSA) and Epworth sleepiness score >or= 10 and Group II, 20 controls. In Group I, polysomnography was performed simultaneously with Holter (specific software to detect sleep apnoea). In Group II, Holter-based detection was utilized. A cutoff value of 10 for the apnoea-hypopnoea index (for polysomnography) or for the respiratory disturbance index (RDI) (for Holter) was considered abnormal. Sleep apnoea was confirmed by polysomnography in 14 patients (70%) in Group I. Holter recordings correctly identified OSA in 11 patients (r = 0.74 with polysomnography; P = 0.0002). Holter showed 78.5% sensitivity, 83.3% specificity, 91.6% positive predictive value, and 62.5% negative predictive value (with polysomnography as the gold standard). The RDI measured by Holter was 19.5 +/- 20 in Group I and 3.9 +/- 4.4 in controls (P < 0.005). The measurement between Holter and polysomnography (Bland and Altman method) showed good correlation (mean 4.7 with 39.4 and -30.1 SD) and a Pearson correlation coefficient (r) of 0.74 (P = 0.0002, 95% CI: 0.44-0.89).
Conclusion:
Holter-based software may constitute an accessible tool on initial suspicion of OSA.
More Related Videos
07:54Drug-Induced Sleep Endoscopy (DISE) with Target Controlled Infusion (TCI) and Bispectral Analysis in Obstructive Sleep Apnea
Published on: December 6, 2016
18:11A Research Method For Detecting Transient Myocardial Ischemia In Patients With Suspected Acute Coronary Syndrome Using Continuous ST-segment Analysis
Published on: December 28, 2012
Related Concept Videos
Holter Monitor: 24-Hour Monitoring
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Sleep Apnea
The condition is more prevalent among...
Dysrhythmias V: Evaluating Dysrhythmias
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for: