Related Experiment Video
Updated: Jun 28, 2026

Magnetic Resonance Derived Myocardial Strain Assessment Using Feature Tracking
Published on: February 12, 2011
Cross-correlation delay to quantify myocardial dyssynchrony from phase contrast magnetic resonance (PCMR) velocity
Jana G Delfino1, Brandon K Fornwalt, Robert L Eisner
1Department of Radiology, Emory University School of Medicine, Atlanta, Georgia 30322, USA. jana.delfino@emory.edu
Purpose:
To apply cross-correlation delay (XCD) analysis to myocardial phase contrast magnetic resonance (PCMR) tissue velocity data and to compare XCD to three established "time-to-peak" dyssynchrony parameters.
Materials And Methods:
Myocardial tissue velocity was acquired using PCMR in 10 healthy volunteers (negative controls) and 10 heart failure patients who met criteria for cardiac resynchronization therapy (positive controls). All dyssynchrony parameters were computed from PCMR velocity curves. Sensitivity, specificity, and receiver operator curve (ROC) analysis for separating positive and negative controls were computed for each dyssynchrony parameter.
Results:
XCD had higher sensitivity (90%) and specificity (100%) for discriminating between normal and patient groups than any of the time-to-peak dyssynchrony parameters. ROC analysis showed that XCD was the best parameter for separating the positive and negative control groups.
Conclusion:
XCD is superior to time-to-peak dyssynchrony parameters for discriminating between subjects with and without dyssynchrony and may aid in the selection of patients for cardiac resynchronization therapy.
Related Concept Videos
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...