Occurrence of polycyclic aromatic hydrocarbons in dust emitted from circulating fluidized bed boilers

B Kozielska1, J Konieczyńiski

  • 1Silesian University of Technology, Faculty of Energy and Environmental Engineering, Department of Air Protection, 2 Akademicka St., 44-101 Gliwice, Poland. Barbara.kozielska@polsl.pl

Environmental Technology
|November 4, 2008
PubMed

Related Concept Videos

Gas Chromatography: Types of Detectors-II01:19

Gas Chromatography: Types of Detectors-II

In gas chromatography, different detectors are employed to meet specific analytical needs. These detectors are often categorized based on their detection mechanisms and the types of compounds they are best suited to analyze. Thermal Conductivity Detectors (TCD), Flame Ionization Detectors (FID), and Electron Capture Detectors (ECD) represent common categories, each with unique operating principles and applications. However, beyond these, several other detectors are designed for more specialized...
Flame Photometry: Overview01:02

Flame Photometry: Overview

Flame photometry, also known as flame emission spectrometry, is a technique used for the qualitative and quantitative analysis of elements present in a sample using a flame as the source of excitation energy. The concept of flame photometry was realized in the early 1860s by Kirchhoff and Bunsen, who discovered that specific elements emit characteristic radiation when excited in flames. The first instrument developed for this purpose was used to measure sodium (Na) in plant ash using a Bunsen...
Aromatic Compounds: Overview01:25

Aromatic Compounds: Overview

In general, the term ‘aromatic’ indicates a pleasant smell or fragrance from fresh flowers, freshly prepared coffee, etc. In the early history of organic chemistry, many benzene derivatives were isolated from the pleasant odor oils of the plants. For example, vanillin was isolated from the oil of vanilla, methyl salicylate from the oil of wintergreen, and cinnamaldehyde from the oil of cinnamon. They all had a pleasant odor; hence the name aromatic was given.
In 1825, Faraday isolated benzene...
Flame Photometry: Lab01:16

Flame Photometry: Lab

In a flame photometer, when a solution like potassium chloride is aspirated into the flame, the solvent evaporates, leaving behind dehydrated salt. This salt dissociates into free gaseous atoms in their ground state. Some of these atoms absorb energy from the flame, leading to their excitation. The excited atoms return to the ground state, emitting photons at characteristic wavelengths. Because only electronic transitions are involved, the resulting emission lines are very narrow. The intensity...
Atomic Emission Spectroscopy: Interference01:30

Atomic Emission Spectroscopy: Interference

In atomic emission spectroscopy (AES), high-temperature atomizers excite a broad range of elements and molecules that generate complex emissions from sources such as oxides, hydroxides, and flame combustion products in the flame or plasma. Several strategies can be employed to minimize spectral interferences caused by overlapping emission lines or bands. These include increasing instrument resolution, choosing alternative emission lines, optimally placing the detector in low-background regions,...