Related Experiment Video
Updated: Jun 28, 2026

Muscle Imbalances: Testing and Training Functional Eccentric Hamstring Strength in Athletic Populations
Published on: May 1, 2018
Kinetic comparison of free weight and machine power cleans
R Murry Jones1, Andrew C Fry, Lawrence W Weiss
1Human Performance Laboratories, The University of Memphis, Memphis, Tennessee, USA.
Abstract:
The purpose of this investigation was to compare the kinetic characteristics of the power clean exercise using either free weight or machine resistance. After familiarization, 14 resistance trained men (mean +/- SD; age = 24.9 +/- 6.2 years) participated in two testing sessions. During the initial testing session, one-repetition maximum performance (1RM) was assessed in either the free weight or machine power clean from the midthigh. This was followed by kinetic assessment of either the free weight or the machine power clean at 85% of 1RM. One week after the initial testing session, 1RM performance, as well as the subsequent kinetic evaluation, were performed for the alternate exercise modality. All performance measures were obtained using a computer-interfaced FiTROdyne dynamometer (Fitronic; Bratislava, Slovakia). Maximum strength (1RM) and average power were significantly greater for the free weight condition, whereas peak velocity and average velocity were greater for the machine condition (p < 0.05). Although peak power was not different between modalities, force at peak power (free weights = 1445 +/- 266 N, machine = 1231 +/- 194 N) and velocity at peak power (free weights = 1.77 +/- 0.28 m x s(-1), machine = 2.20 +/- 0.24 m x s(-1)) were different (p < 0.05). It seems that mechanical limitations of the machine modality (i.e., lift trajectory) result in different load capacities that produce different kinetic characteristics for these two lifting modalities.
More Related Videos
12:59Improving Strength, Power, Muscle Aerobic Capacity, and Glucose Tolerance through Short-term Progressive Strength Training Among Elderly People
Published on: July 5, 2017
07:44Construction of Constant-Load (Isotonic) and Constant-Velocity (Isokinetic) Torque-Velocity-Power Profiles In vivo for the Rat Plantar Flexors
Published on: October 3, 2025
Related Concept Videos
Mechanical Efficiency of Real Machines
However, in reality, no machine can be truly ideal, and all of them experience some...
Comparison Between Electrical And Gravitational Forces
Since both are inverse square law forces, the distance gets canceled when the ratio of the two forces is considered. Instead, the ratio of the electrical and gravitational forces depends on...
Machines: Problem Solving II
Machines: Problem Solving I
The toggle clamp system is a machine structure consisting of movable, pin-connected multi-force members that form a stabilized system to transmit forces. The...
Power Expended by a Constant Force
Machines
A free-body diagram of the...