Related Experiment Video
Updated: Jun 28, 2026

Large-scale Reconstructions and Independent, Unbiased Clustering Based on Morphological Metrics to Classify Neurons in Selective Populations
Published on: February 15, 2017
Sample sufficiency and number of modes to retain in statistical shape modelling
Lin Mei1, Michael Figl, Daniel Rueckert
1Dept. of Biosurgery and Surgical Technology Imperial College London, UK. l.mei@imperial.ac.uk
Abstract:
Statistical shape modelling is a popular technique in medical imaging, but the issue of sample size sufficiency is not generally considered. Also the number of principal modes retained is often chosen simply to cover a percentage of the total variance. We show that these simple rules are unreliable. We propose a new method that uses bootstrap replication and a t-test comparison with noise to decide whether each mode direction has stabilised. We establish mode correspondence by minimising the distance between the space spanned by the replicates and their mean. By retaining only stable modes, our method distinguishes real anatomical variation from modes dominated by random noise. This provides a lower stopping rule when the sample is small and converges as the sample size increases. We use this convergence to determine sample sufficiency. For validation we use synthetic datasets of the left ventricle generated with a known number of structural modes and added noise. Our stopping rule detected the correct number of modes to retain where other methods failed. The methods were also tested on real 2D (22 points) and 3D (500 points) face data, retaining 24 and 70 modes with sample sufficiency being reached at approximately 50 and 150 samples respectively. For a 3D database of the left ventricle (527 points), 319 samples are not sufficient, but at this level we can retain around 55 stable modes. Our method provides a principled foundation for appropriate selection of the number of modes to retain and determination of sample size sufficiency for statistical shape modelling.
Related Concept Videos
What is a Mode?
There can be more than one mode in a data set if multiple values have the same highest frequency. For instance, suppose that the Statistics exam scores of 20 students are: 50; 53; 59; 59; 63; 63; 72; 72; 72; 72; 72; 76; 78; 81; 83; 84; 84; 84; 90; 93. Here, the mode is 72, as it occurs most frequently, five times.
A data set with two modes is called bimodal. For example,...
Expected Frequencies in Goodness-of-Fit Tests
Sampling Distribution
Skewness
The longer the tail of the plot on one side, the more skewed it is. The skewness of a data set’s values suggests that the measures of central tendency are...
Sampling Methods: Sample Types
Solid samples include a variety of substances, such as sediments from water bodies, soil, metals, and biological tissues. Two standard methods for extracting sediments from water bodies are grab sampling and piston coring. Grab sampling involves using a device to collect a discrete sediment sample from the bottom of a water body with minimal disturbance. Grab samples do not always represent the entire area due to...
Sample Size Calculation
The sample size for the given experiment or sampling effort is fundamental to any study design. Sample size decides the number of...