Drug-eluting coronary stents: hypersensitivity reactions to paclitaxel. A case report
L Pfoch1, V Mahler, M Sticherling
1Department of Dermatology, University Hospital of Erlangen, Erlangen, Germany.
Background:
Drug-eluting stents become increasingly popular for the treatment of coronary artery disease. Consequently, side effects including hypersensitivity reactions have to be anticipated.
Case Report:
Here we report on a patient with an anaphylactic reaction 2 weeks after implantation of a polymer-based paclitaxel-eluting stent (Taxus, Boston Scientific). The patient presented with disseminated wheals, pruritus, bronchial asthma and acute synovitis. The reaction was successfully treated with initial intravenous injection followed by oral antihistamine treatment for 1 month until all stent-bound paclitaxel was assumed to be eluted. Thereafter no further anaphylactic reaction occurred.
Conclusion:
This sequence of events points towards a causal relation of the stent implantation and hypersensitivity reaction with a central role of paclitaxel. The increasing use of this type of stent should therefore be carefully monitored for such adverse reactions.
Related Concept Videos
Drug Toxicity: Allergic Reactions
Drug toxicity: Idiosyncratic Reactions
Allergic Reactions
Hypersensitivity Reactions: Delayed Hypersensitivity Reactions
Allergic Reactions: Anaphylaxis
Treatment for Pulmonary Arterial Hypertension: Endothelin Receptor Antagonists
ETs are synthesized through a complex sequence of enzymatic steps, primarily involving an enzyme referred to as endothelin-converting enzyme (ECE). Of...