Related Experiment Video
Updated: Jun 28, 2026

Integrating Augmented Reality Tools in Breast Cancer Related Lymphedema Prognostication and Diagnosis
Published on: February 6, 2020
An automated approach for estimation of breast density
John J Heine1, Michael J Carston, Christopher G Scott
1H. Lee Moffitt Cancer Center and Research Institute, Tampa, Florida, USA.
Abstract:
Breast density is a strong risk factor for breast cancer; however, no standard assessment method exists. An automated breast density method was modified and compared with a semi-automated, user-assisted thresholding method (Cumulus method) and the Breast Imaging Reporting and Data System four-category tissue composition measure for their ability to predict future breast cancer risk. The three estimation methods were evaluated in a matched breast cancer case-control (n = 372 and n = 713, respectively) study at the Mayo Clinic using digitized film mammograms. Mammograms from the craniocaudal view of the noncancerous breast were acquired on average 7 years before diagnosis. Two controls with no previous history of breast cancer from the screening practice were matched to each case on age, number of previous screening mammograms, final screening exam date, menopausal status at this date, interval between earliest and latest available mammograms, and residence. Both Pearson linear correlation (R) and Spearman rank correlation (r) coefficients were used for comparing the three methods as appropriate. Conditional logistic regression was used to estimate the risk for breast cancer (odds ratios and 95% confidence intervals) associated with the quartiles of percent breast density (automated breast density method, Cumulus method) or Breast Imaging Reporting and Data System categories. The area under the receiver operator characteristic curve was estimated and used to compare the discriminatory capabilities of each approach. The continuous measures (automated breast density method and Cumulus method) were highly correlated with each other (R = 0.70) but less with Breast Imaging Reporting and Data System (r = 0.49 for automated breast density method and r = 0.57 for Cumulus method). Risk estimates associated with the lowest to highest quartiles of automated breast density method were greater in magnitude [odds ratios: 1.0 (reference), 2.3, 3.0, 5.2; P trend < 0.001] than the corresponding quartiles for the Cumulus method [odds ratios: 1.0 (reference), 1.7, 2.1, and 3.8; P trend < 0.001] and Breast Imaging Reporting and Data System [odds ratios: 1.0 (reference), 1.6, 1.5, 2.6; P trend < 0.001] method. However, all methods similarly discriminated between case and control status; areas under the receiver operator characteristic curve were 0.64, 0.63, and 0.61 for automated breast density method, Cumulus method, and Breast Imaging Reporting and Data System, respectively. The automated breast density method is a viable option for quantitatively assessing breast density from digitized film mammograms.
More Related Videos
15:48Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
Published on: December 15, 2014
13:43Intraductal Delivery and X-ray Visualization of Ethanol-Based Ablative Solution for Prevention and Local Treatment of Breast Cancer in Mouse Models
Published on: April 1, 2022