Related Experiment Video
Updated: Jun 28, 2026

A Complete Method for Evaluating the Performance of Photocatalysts for the Degradation of Antibiotics in Environmental Remediation
Published on: October 6, 2022
Electrochemical heterogeneous catalytic degradation of wastewater containing phenol
Baojun Jia1, Dong Zhang, Ai L Zhang
1Institute of Resources & Environment, Henan Polytechnic University, Jiaozuo, Henan, China. jbjqjl@yahoo.com.cn
Abstract:
An electrochemical-heterogeneous catalytic process was applied to remove phenol from wastewater. Three key factors-applied potential, supporting electrolyte concentration, and pH-were tested for their effects on the phenol removal. The optimal condition was determined as an applied potential of 25 V, Na(2)SO(4) concentration of 500 mg L(-1), and a pH of 2.5. Under the optimal condition, the phenol and chemical oxygen demand (COD) removals were 83.7% and 42.9%, respectively. The apparent kinetics of phenol removal could be expressed as a pseudo first-order reaction. In addition, a possible mechanism of phenol degradation was proposed based on the intermediate products.
More Related Videos
Related Concept Videos
Microbial Wastewater Treatment
Catalysis
Catalysis
Heterogeneous Catalysis
Microbial Bioremediation of Pesticides
Microbial Bioremediation of Hydrocarbons