Related Experiment Video
Updated: Jun 28, 2026

Quantitative Mapping of Specific Ventilation in the Human Lung using Proton Magnetic Resonance Imaging and Oxygen as a Contrast Agent
Published on: June 5, 2019
Urinary oxygen tension measurement in humans using magnetic resonance imaging
Zhen J Wang1, Bonnie N Joe, Fergus V Coakley
1Department of Radiology, University of California San Francisco, Abdominal Imaging, San Francisco, CA 94143-0628, USA. jane.wang@radiology.ucsf.edu
Rationale And Objectives:
Renal medullary hypoxia is frequently implicated in renal dysfunction, and urinary oxygen tension (PO(2)) in the renal pelvis can be used as a surrogate for the adjacent renal medullary oxygenation. We sought to assess the feasibility of magnetic resonance (MR) quantification of urinary PO(2) in humans.
Materials And Methods:
The longitudinal relaxivity (R1) of fluids is linearly related to PO(2), allowing MR quantification of urinary PO(2). We imaged urine phantoms with a range of PO(2) using a real-time saturation recovery T2-prepped single-shot fast spin-echo sequence to calibrate urine R1 values to PO(2). Following institutional review board approval, we imaged the urinary bladders of seven healthy subjects while they were breathing room air and the renal pelvis of nine healthy subjects while they were breathing room air or 100% oxygen via facemask. The renal pelvic urine PO(2) was compared before, during, and after 100% oxygen breathing.
Results:
Our phantom study confirmed that urine R1 is linearly related to PO(2): PO(2) (mm Hg) = (R1 - 0.2253 s(-1))/(2.61e(-4) s(-1)/mm Hg). The mean bladder urine PO(2) ranged from 23 to 45 mm Hg among the seven subjects. Successful MR measurements of renal pelvic urine PO(2) were obtained in seven of nine healthy subjects. Following 100% O(2) breathing, the renal pelvic urine PO(2) showed a significant mean increase of 29 mm Hg (P < .05).
Conclusions:
We show that MR quantification of urinary PO(2) is feasible. Noninvasive renal pelvic urine PO(2) determinations could serve as a valuable indirect measure for renal medullary oxygenation, allowing for clinical investigations of the role of renal medullary hypoxia in renal disease.
More Related Videos
08:35Oxygenation-sensitive Cardiac MRI with Vasoactive Breathing Maneuvers for the Non-invasive Assessment of Coronary Microvascular Dysfunction
Published on: August 17, 2022
12:29Magnetic Resonance Imaging Quantification of Pulmonary Perfusion using Calibrated Arterial Spin Labeling
Published on: May 30, 2011
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies IV: Magnetic Resonance Imaging