Related Experiment Video
Updated: Jun 28, 2026

Measuring 3D In-vivo Shoulder Kinematics using Biplanar Videoradiography
Published on: March 12, 2021
MR-guided direct arthrography of the glenohumeral joint
E Soh1, P W P Bearcroft, M J Graves
1Department of Radiology, Addenbrooke's Hospital, Cambridge University Hospitals NHS Foundation Trust, Cambridge, UK. esoh@doctors.org.uk
Aim:
To evaluate the feasibility of magnetic resonance (MR)-guided direct arthrography of the glenohumeral joint with a 1.5 T MR system, performing the entire procedure in a single MR examination.
Materials And Methods:
MR-guided direct arthrography was performed on 11 patients. MR imaging guidance and interactive MR fluoroscopy, with in-room control and display system, were used for needle placement and contrast medium injection. The outcome measures were success or failure of joint puncture, the time taken for introduction of contrast medium, and the diagnostic quality of the subsequent MR arthrography images.
Results:
Contrast medium was successfully instilled into the joint and diagnostic quality MR arthrography images were obtained in all cases. The median time from initial placement of the skin marker to introduction of the contrast medium was 17 min (range 11-29 min). There were no immediate post-procedure complications.
Conclusion:
Accurate needle placement is feasible in a single MR examination on a commercial 1.5 T closed-bore MR system, using an in-room control and display system together with interactive fluoroscopic imaging, and this was used to provide direct MR arthrography in this study.